4.7 Review

Positioning time in range in diabetes management

Journal

DIABETOLOGIA
Volume 63, Issue 2, Pages 242-252

Publisher

SPRINGER
DOI: 10.1007/s00125-019-05027-0

Keywords

CGM; Diabetes complications; HbA(1c); Hyperglycaemia; Hypoglycaemia; Review; Time below range; Time in range

Funding

  1. Diabetes Canada
  2. Canadian Institutes of Health Research
  3. RDV Foundation
  4. Heart and Stroke Foundation of Canada
  5. Kidney Foundation of Canada

Ask authors/readers for more resources

Recent upswings in the use of continuous glucose monitoring (CGM) technologies have given people with diabetes and healthcare professionals unprecedented access to a range of new indicators of glucose control. Some of these metrics are useful research tools and others have been welcomed by patient groups for providing insights into the quality of glucose control not captured by conventional laboratory testing. Among the latter, time in range (TIR) is an intuitive metric that denotes the proportion of time that a person's glucose level is within a desired target range (usually 3.9-10.0 mmol/l [3.5-7.8 mmol/l in pregnancy]). For individuals choosing to use CGM technology, TIR is now often part of the expected conversation between patient and healthcare professional, and consensus recommendations have recently been produced to facilitate the adoption of standardised TIR targets. At a regulatory level, emerging evidence linking TIR to risk of complications may see TIR being more widely accepted as a valid endpoint in future clinical trials. However, given the skewed distribution of possible glucose values outside of the target range, TIR (on its own) is a poor indicator of the frequency or severity of hypoglycaemia. Here, the state-of-the-art linking TIR with complications risk in diabetes and the inverse association between TIR and HbA(1c) are reviewed. Moreover, the importance of including the amount and severity of time below range (TBR) in any discussions around TIR and, by inference, time above range (TAR) is discussed. This review also summarises recent guidance in setting 'time in ranges' goals for individuals with diabetes who wish to make use of these metrics. For most people with type 1 or type 2 diabetes, a TIR >70%, a TBR <3.9 mmol/l of <4%, and a TBR <3.0 mmol/l of <1% are recommended targets, with less stringent targets for older or high-risk individuals and for those under 25 years of age. As always though, glycaemic targets should be individualised and rarely is that more applicable than in the personal use of CGM and the data it provides.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available