4.7 Article

Performance evaluation of twelve low-cost PM2.5 sensors at an ambient air monitoring site

Journal

ATMOSPHERIC ENVIRONMENT
Volume 216, Issue -, Pages -

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.atmosenv.2019.116946

Keywords

Air quality; Fine particulate matter; Low-cost sensors; Optical particle counter; Performance evaluation

Funding

  1. South Coast AQMD

Ask authors/readers for more resources

A variety of low-cost sensors are now available on the consumer market for measuring air pollutants. The use of these low-cost sensors for ambient air monitoring applications is increasing and includes fence-line or near-source monitoring, community monitoring, emergency response, hot-spot identification, mobile monitoring, epidemiological studies, and supplemental monitoring to improve the spatial-temporal resolution of current monitoring networks. Evaluating and understanding the performance of these devices is necessary to properly interpret the results and reduce confusion when low-cost sensor measurements are not in agreement with measurements from regulatory-grade instrumentation. Systematic and comprehensive field and laboratory studies comparing low-cost sensors with regulatory-grade instrumentation are necessary to characterize sensor performance. This paper presents the results of 12 particulate matter (PM) sensors measurement of PM2.5 (particles with aerodynamic diameter less than 2.5 mu m) tested under ambient conditions against a federally equivalent method (FEM) instrument at an ambient air monitoring station in Riverside, CA spanning over a 3-year period from 02/05/15 to 03/27/18. Sensors were evaluated in triplicate with a typical time duration of 8-week. Performance evaluation results found 6 of the 12 sensor triplicates with average R-2 values >= 0.70 for PM2.5 concentrations less than 50 mu g/m(3). Within this subset, the Mean Absolute Error (MAE) ranged from 4.4 to 7.0 mu g/m(3) indicating the need for caution when interpreting data from these sensors. Additional analysis revealed that the impact of relative humidity on sensor performance varied between models with several models exhibiting increased bias error with increasing humidity. Results indicate that a number of these sensors have potential as useful tools for characterizing PM2.5 levels in ambient environments when data is interpreted and understood correctly with regard to existing ambient air quality networks. The performance evaluation results are specific for Riverside, CA under non-repeatable ambient weather conditions and particle properties with the expectation that performance evaluation testing at other locations with different particle properties and weather conditions would yield similar but non-identical results.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available