4.8 Article

Synthesis and Application of CeO2/SnS2 Heterostructures as a Highly Efficient Coreaction Accelerator in the Luminol-Dissolved O2 System for Ultrasensitive Biomarkers Immunoassay

Journal

ANALYTICAL CHEMISTRY
Volume 91, Issue 21, Pages 14066-14073

Publisher

AMER CHEMICAL SOC
DOI: 10.1021/acs.analchem.9b03796

Keywords

-

Funding

  1. National Key Scientific Instrument and Equipment Development Project of China [21627809]
  2. National Natural Science Foundation of China [21575050, 21505051, 21777056]
  3. Special Foundation for Taishan Scholar Professorship of Shandong Province [ts201712052]
  4. Jinan Scientific Research Leader Workshop Project [2018GXRCO24]

Ask authors/readers for more resources

Electrocheluminescence (ECL) immunoassay amplified by coreaction accelerators has experienced major breakthroughs in ultrasensitive detection of biomarkers. Herein, CeO2/SnS2 heterostructures were synthesized and applied as a novel coreaction accelerator to enhance the ECL efficiency of the luminol dissolved O-2 system for the first time. Benefiting from the well-matched lattice spacing, ultrafine CeO2 nanoparticles (NPs) were grown in situ on layered SnS2 nanosheets (NSs) with improved dispersion. CeO2/SnS2 as an electroactive substrate can remarkably accelerate the generation of abundant superoxide anion radicals (O-2(center dot-)) to react with luminol anion radical (L center dot-), achieving about 2-fold stronger ECL intensity than that of pure CeO2 NPs. To avoid harsh chemical synthesis of conventional ECL labels and simplify the antibody conjugation process, ferritin (Ft) was served as a natural nanocarrier to immobilize luminol molecules (Lum@Ft) via a one-step linkage, whose protein nanocage can easily connect with the detection antibody. Moreover, a robust site-oriented immobilization strategy using HWRGWVC heptapeptide as specific capturer was further adopted to maintain the bioactivity of the capture antibody on the amine-functionalized CeO2/SnS2 surface, which promoted the incubation efficiency markedly. On account of this advanced sensing strategy, a brand new biosensor was constructed for the accurate detection of heart failure biomarkers, which performed with favorable linearity in the range of 0.0001-50 ng/mL and achieved the detection limit of 36 fg/mL.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available