4.5 Article

Bayesian Estimation of CBF Measured by DSC-MRI in Patients with Moyamoya Disease: Comparison with 15O-Gas PET and Singular Value Decomposition

Journal

AMERICAN JOURNAL OF NEURORADIOLOGY
Volume 40, Issue 11, Pages 1894-1900

Publisher

AMER SOC NEURORADIOLOGY
DOI: 10.3174/ajnr.A6248

Keywords

-

Funding

  1. Japan Society for the Promotion of Science [26305031, 16H06280]
  2. Grants-in-Aid for Scientific Research [26305031] Funding Source: KAKEN

Ask authors/readers for more resources

BACKGROUND AND PURPOSE: CBF analysis of DSC perfusion using the singular value decomposition algorithm is not accurate in patients with Moyamoya disease. This study compared the Bayesian estimation of CBF against the criterion standard PET and singular value decomposition methods in patients with Moyamoya disease. MATERIALS AND METHODS: Nineteen patients with Moyamoya disease (10 women; 22?52 years of age) were evaluated with both DSC and O-15-gas PET within 60 days. DSC-CBF maps were created using Bayesian analysis and 3 singular value decomposition analyses (standard singular value decomposition, a block-circulant deconvolution method with a fixed noise cutoff, and a block-circulant deconvolution method that adopts an occillating noise cutoff for each voxel according to the strength of noise). Qualitative and quantitative analyses of the Bayesian-CBF and singular value decomposition?CBF methods were performed against O-15-gas PET and compared with each other. RESULTS: In qualitative assessments of DSC-CBF maps, Bayesian-CBF maps showed better visualization of decreased CBF on PET (sensitivity = 62.5%, specificity = 100%, positive predictive value = 100%, negative predictive value = 78.6%) than a block-circulant deconvolution method with a fixed noise cutoff and a block-circulant deconvolution method that adopts an oscillating noise cutoff for each voxel according to the strength of noise (P < .03 for all except for specificity). Quantitative analysis of CBF showed that the correlation between Bayesian-CBF and PET-CBF values (? = 0.46, P < .001) was similar among the 3 singular value decomposition methods, and Bayesian analysis overestimated true CBF (mean difference, 47.28 mL/min/100 g). However, the correlation between CBF values normalized to the cerebellum was better in Bayesian analysis (? = 0.56, P < .001) than in the 3 singular value decomposition methods (P < .02). CONCLUSIONS: Compared with previously reported singular value decomposition algorithms, Bayesian analysis of DSC perfusion enabled better qualitative and quantitative assessments of CBF in patients with Moyamoya disease.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available