Journal
ACS APPLIED MATERIALS & INTERFACES
Volume 11, Issue 43, Pages 40134-40150Publisher
AMER CHEMICAL SOC
DOI: 10.1021/acsami.9b15179
Keywords
chemically robust cationic MOF; humid CO2 capture; fast responsive detection; TNP and oxo-anion sensing; DFT calculation
Funding
- DST-SERB [ECR/2016/000156]
- CSIR [MLP-0028]
- CSIR, New Delhi, India [31/028(0252)/2019-EMR-I]
Ask authors/readers for more resources
Metal-organic frameworks (MOFs) show distinctive superiority for carbon dioxide (CO2) capture and luminescent sensing of toxic pollutants over other materials where combination of both of these properties together with improvement of hydrolytic stability and pore functionality is critical to environmental remediation applications. The Ni(II) framework [Ni-2(mu 2OH)(azdc)(tpim)](NO3)center dot 6DMA center dot 6MeOH (CSMCRI-3) (tpim = 44'4(2)-(1H-imidazole-245-triyl)tripyridine H(2)azdc = azobenzene-44'-dicarboxylic acid DMA = dimethylacetamide CSMCRI = Central Salt & Marine Chemicals Research Institute) encompassing cationic [Ni-2(mu(2)-OH)(CO2)(2)] SBUs is solvothermally synthesized from nitrogen-rich and highly fluorescent organic struts. The noninterpenetrated structure containing free nitrogen atom affixed microporous channels is stable in diverse organic solvents and weakly basic and acidic aqueous solutions. The activated MOF (3a) exhibits strong CO2-framework interaction and extremely selective CO2 adsorption over N-2 (292.5) and CH4 (11.7). Importantly water vapor exposure does not affect the surface area and/or multiple CO2 uptake-release cycles signifying potential of the porous structure for long-term use under humid conditions. Aqueous-phase sensing studies illustrate extremely specific and ultrafast detection of explosive 246-trinitrophenol (TNP) via remarkable fluorescence quenching (K-SV = 1.3 x 10 (5) M-1) with a 0.25 ppm limit of detection (LOD). Furthermore 3a serves as unique luminescent probe for highly discriminative and quick responsive detection of three noxious oxo-anions (Cr2O7 (2-) CrO4 (2-) MnO4-) in water via noteworthy turn-off responses and extreme low LODs (Cr2O7 (2-) 0.9; CrO4 (2-) 0.29; MnO4- 0.25 ppm). It is imperative to stress the outstanding reusability of the MOF toward multicyclic sensing of all four major water contaminants alongside visible colorimetric changes upon individual analyte detection. Mechanistic insights in light of the electron transfer route together with density functional theory calculations portray the influence of pore functionalization in framework-analyte interactions including alternation in energy levels where varying degrees of contribution of energy transfer explicitly authenticates high quenching of the material.
Authors
I am an author on this paper
Click your name to claim this paper and add it to your profile.
Reviews
Recommended
No Data Available