4.7 Article

Vacuum-assisted sorbent extraction: An analytical methodology for the determination of ultraviolet filters in environmental samples

Journal

TALANTA
Volume 208, Issue -, Pages -

Publisher

ELSEVIER
DOI: 10.1016/j.talanta.2019.120390

Keywords

Vacuum-assisted sorbent extraction; Ultraviolet filters; Gas chromatography; Mass spectrometry; Environmental analysis

Funding

  1. National Science Foundation [CHE-1709372]

Ask authors/readers for more resources

Vacuum-assisted sorbent extraction (VASE) has been applied in combination with gas chromatography-mass spectrometry for the determination of UV filters in water samples. VASE is a variant of headspace extraction which was developed in conjunction with the sorbent pen (SP) technology. This technique combines the advantages of both stir-bar assisted extraction and headspace solid-phase microextraction. The SP traps allowed both reduced pressure in-vial extraction and direct thermal desorption via a unique gas chromatographic injection port. The main parameters that affect the performance of VASE, including both extraction and desorption conditions, were extensively optimized. Under optimum conditions, extraction required 10 mL of sample within 40 mL vials, pH 3.5, similar to 30 s of air-evacuation, 14 h incubation at 70 degrees C, stirring at 200 rpm, and a final water management step conducted at similar to -17 degrees C for 15 min. Optimal thermal desorption required preheating at 260 degrees C for 2 min followed by desorption at 300 degrees C for 2min. The beneficial effect of reduced-pressure extraction was demonstrated by comparing the UV filter extraction time profiles collected using VASE to an analogous atmospheric pressure procedure, resulting in up to a 3-fold improvement under optimized conditions. The VASE methodology enabled simultaneous extractions using different SPs without compromising the method reproducibility, which increases the overall sample throughput. The method was characterized by low limits of detection, from 0.5 to 80 ng L-1, and adequate reproducibility, with inter-SP and inter-day relative standard deviation lower than 14%. Tap and lake water was successfully analyzed with the proposed methodology, resulting in relative recoveries of spiked samples ranging between 70.0 and 120%.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available