4.7 Article

Duplex mode tilt measurements based on a MEMS biaxial resonant accelerometer

Journal

SENSORS AND ACTUATORS A-PHYSICAL
Volume 296, Issue -, Pages 222-234

Publisher

ELSEVIER SCIENCE SA
DOI: 10.1016/j.sna.2019.06.024

Keywords

MEMS tilt sensor; Resonant accelerometer; Duplex mode; Multi-functional tilt measurement

Funding

  1. National Natural Science Foundation of China [51875521]
  2. Zhejiang Provincial Natural Science Foundation of China [1219E050002]
  3. Science Fund for Creative Research Groups of National Natural Science Foundation of China [51821093]

Ask authors/readers for more resources

This paper firstly reports the duplex mode tilt measurements (biaxial tilt measurement with small angle range and uniaxial tilt measurement with large angle range) based on a micro electromechanical system (MEMS) biaxial resonant accelerometer. For the accelerometer, two pairs of double-ended tuning fork (DETF) resonators are the sensing elements and they are integrated with a single proof mass. The two-stage microleverage mechanisms, possessing higher amplification factor, amplify and translate the weight component to the resonators. The adoption of decoupling beams lower the cross impact and allow the simultaneous differential measurement of tilt angles acting along two orthogonal axes. Based on the biaxial sensing structure, the biaxial tilt measurement is realized on the two orthogonal sensing axes. By the combination of the four DETFs resonant frequencies at each angular position, the linear range of uniaxial tilt measurement is extended. For the biaxial tilt measurement with small angle range, the experiments demonstrate a high sensitivity (X-axis: 4.351 Hz/deg and Y-axis: 5.257 Hz/deg) and a low cross-axis sensitivity (X-axis: 0.180 Hz/deg and Y-axis: 0.202 Hz/deg) for a +/- 40 degrees biaxial tilt angle range. For the uniaxial tilt measurement with large angle range, the device shows an average sensitivity of 3.973 Hz/deg for a +/- 90 degrees range. In addition, the close-loop self-oscillation is realized and the minimum Allan deviation of 68 ppb is obtained. The performance makes the device a potentially attractive option for compact, multi-functional and highly-sensitive tilt measurements. (C) 2019 Published by Elsevier B.V.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available