4.6 Article

Bioengineered analog of stromal cell-derived factor 1α preserves the biaxial mechanical properties of native myocardium after infarction

Journal

Publisher

ELSEVIER
DOI: 10.1016/j.jmbbm.2019.04.014

Keywords

Biaxial tension; Myocardial infarction; Ventricular remodeling; Angiogenic therapy

Funding

  1. National Institutes of Health [5R01HL089315-11]
  2. American Heart Association [18POST33990223, 17POST33410497]

Ask authors/readers for more resources

Adverse remodeling of the left ventricle (LV) after myocardial infarction (MI) results in abnormal tissue biomechanics and impaired cardiac function, often leading to heart failure. We hypothesized that intramyocardial delivery of engineered stromal cell-derived factor la analog (ESA), our previously-developed supra-efficient proangiogenic chemokine, preserves biaxial LV mechanical properties after MI Male Wistar rats (n = 45) underwent sham surgery (n = 15) or permanent left anterior descending coronary artery ligation. Rats sustaining MI were randomized for intramyocardial injections of either saline (100 mu L, n = 15) or ESA (6 mu g/kg, n = 15), delivered at four standardized borderzone sites. After 4 weeks, echocardiography was performed, and the hearts were explanted. Tensile testing of the anterolateral LV wall was performed using a displacement-controlled biaxial load frame, and modulus was determined after constitutive modeling. At 4 weeks post-MI, compared to saline controls, ESA-treated hearts had greater wall thickness (1.68 +/- 0.05 mm vs 1.42 +/- 0.08 mm, p = 0.008), smaller end-diastolic LV internal dimension (6.88 +/- 0.29 mm vs 7.69 +/- 0.22 mm, p = 0.044), and improved ejection fraction (62.8 +/- 3.0% vs 49.4 +/- 4.5%, p = 0.014). Histologic analysis revealed significantly reduced infarct size for ESA-treated hearts compared to saline controls (29.4 +/- 2.9% vs 41.6 +/- 3.1%, p = 0.021). Infarcted hearts treated with ESA exhibited decreased modulus compared to those treated with saline in both the circumferential (211.5 +/- 6.9 kPa vs 264.3 +/- 12.5 kPa, p = 0.001) and longitudinal axes (194.5 +/- 6.5 kPa vs 258.1 +/- 14.4 kPa, p < 0.001). In both principal directions, ESA-treated infarcted hearts possessed similar tissue compliance as sham non-infarcted hearts. Overall, intramyocardial ESA therapy improves post-MI ventricular remodeling and function, reduces infarct size, and preserves native LV biaxial mechanical properties.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available