PEMFC purging at low operating temperatures: An experimental approach

Journal

INTERNATIONAL JOURNAL OF ENERGY RESEARCH
Volume 43, Issue 13, Pages 7496-7507

Publisher

WILEY
DOI: 10.1002/er.4783

Keywords

dead-ended anode; energy efficiency; fuel cell; PEMFC; purge interval; purge strategy; purging

Ask authors/readers for more resources

In this paper, the effect of operating temperature on optimal purge interval for maximum energy efficiency in a proton exchange membrane fuel cell (PEMFC) with dead-ended anode (DEA) was experimentally investigated. The study was conducted with a focus on challenges associated with operation at temperatures lower than the recommended designed temperature. With DEA, gradual voltage drop happens due to the accumulation of water and impurities such as nitrogen. Hence, periodic purging of the anode side is required to remove excess water and impurities that are accumulated at the anode side over time. Short purge intervals increase hydrogen loss that translates into low fuel utilisation, whereas long purge intervals result in voltage drop due to high water and impurity accumulations. Therefore, an optimal purge strategy should be implemented to maximise the stack energy efficiency. Depending on the operating conditions and loads, there are instances that a fuel cell stack operates at temperatures lower than its recommended designed temperature. Considering the temperature effect on the cell water management, operating temperature is an important factor to consider for optimising the purge strategy in PEMFCs. At lower operating temperatures (ie, below 50 degrees C), more water is formed in liquid form, which makes the optimisation of purge strategy more challenging. For a stack temperature of 40 degrees C, it was observed that with an increase in stack current from 0.25 to 0.45 A cm(-2), the optimal purge interval decreases from 90 seconds to around 45 seconds, respectively. Increasing the stack temperature from 40 degrees C to 50 degrees C resulted in an increase in the optimal purge interval to 120 seconds and 90 seconds for stack currents of 0.25 (ie, low current density) and 0.45 A cm(-2), respectively. At lower operating temperatures, more frequent purging schedules are needed accordingly to remove the liquid water from the cell. These results indicated that at lower operating temperatures, water accumulation at the anode side becomes more dominant compared with higher operating temperatures.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available