4.7 Article

Ultrafast 3D Ultrasound Localization Microscopy Using a 32 x 32 Matrix Array

Journal

IEEE TRANSACTIONS ON MEDICAL IMAGING
Volume 38, Issue 9, Pages 2005-2015

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TMI.2018.2890358

Keywords

Ultrasound; microbubbles ULM; super-resolution; 4D

Funding

  1. Agence Nationale de la Recherche under Project ANR Tremplin Resolve Stroke
  2. European Research Council under the European Union Horizon H2020 programme/ERC Consolidator grant [772786-ResolveStroke]
  3. [ANR-10-IDEX-0001-02 PSL]

Ask authors/readers for more resources

Ultrasound localization microscopy can map blood vessels with a resolution much smaller than the wavelength by localizing microbubbles. The current implementations of the technique are limited to 2-D planes or small fields of view in 3-D. These suffer from minute-long acquisitions, out-of-plane microbubbles, and tissue motion. In this paper, we exploit the recent development of 4D ultrafast ultrasound imaging to insonify an isotropic volume up to 20 000 times per second and perform localization microscopy in the three dimensions. Specifically, a 32 x 32 elements, 9-MHz matrix-array probe connected to a 1024-channel programmable ultrasound scanner was used to achieve sub-wavelength volumetric imaging of both the structure and vector flow of a complex 3D structure (a main canal branching out into two side canals). To cope with the large volumes and the need to localize the bubbles in the three dimensions, novel algorithms were developed based on deconvolution of the beamformed microbubble signal. For tracking, individual particles were paired following a Munkres assignment method, and velocimetry was done following a Lagrangian approach. ULM was able to clearly represent the 3-D shape of the structure with a sharp delineation of canal edges (as small as 230 mu m) and separate them with a spacing as low as 52 mu m. The compounded volume rate of 500 Hz was sufficient to describe velocities in 2.5-150-mm/s range and to reduce the maximum acquisition time to 12 s. This paper demonstrates the feasibility of in vitro 3-D ultrafast ultrasound localization microscopy and opens up the way toward in vivo volumetric ULM.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available