4.6 Article

Self-Scanned HIFU Ablation of Moving Tissue Using Real-Time Hybrid US-MR Imaging

Journal

IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING
Volume 66, Issue 8, Pages 2182-2191

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TBME.2018.2885233

Keywords

Focused ultrasound; thermal ablation; PRFS thermometry; hybrid US MR imaging; motion compensation

Funding

  1. Swiss National Science Foundation [CR33I3_143980]
  2. La fondation pour la lutte contre le cancer et pour des recherches medicobiologiques, Geneva, Switzerland
  3. Swiss National Science Foundation (SNF) [CR33I3_143980] Funding Source: Swiss National Science Foundation (SNF)

Ask authors/readers for more resources

Objective: High intensity focused ultrasound (HIFU) treatment in the abdominal cavity is challenging due to the respiratory motion. In the self-scanning HIFU ablation method, the focal spot is kept static and the heating pattern is obtained through natural tissue motion. This paper describes a novel approach for modulating the HIFU power during self-scanning in order to compensate for the effect of tissue motion on thermal buildup. Methods: The therapy, using hybrid ultrasound (US)/magnetic resonance (MR) imaging, consists of detecting and tracking speckle on US images in order to predict the next tissue position, and modulating the HIFU power according to the tissue speed in order to obtain a rectilinear pattern of uniform temperature elevation. Experiments were conducted on ex vivo tissue subjected to a breathing-like motion generated by an MR-compatible robot and sonicated by a phased array HIFU transducer. Results: US andMR data were free from interferences. For both periodic and non-periodic motion, MR temperature maps showed a substantial improvement in the uniformity of the temperature elevation by using acoustic power modulation. Conclusion: The presented method does not require a learning stage and enables a duty cycle close to 100%, higher average acoustic intensity and avoidance of side lobe effects versus performing HIFU beam steering to compensate tissue motion. Significance: To our knowledge, the proposed method provides the first experimental validation of the self-scanning HIFU ablation paradigm via a real-time hybrid MRI/US imaging, opening the path toward self-scanning in vivo therapies.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available