Biomechanical analysis of anterior pelvic ring fractures with intact peripelvic soft tissues: a cadaveric study

Journal

EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY
Volume 47, Issue 1, Pages 187-193

Publisher

SPRINGER HEIDELBERG
DOI: 10.1007/s00068-019-01213-2

Keywords

Biomechanics; Pelvis; Peripelvic soft tissues; Anterior pelvic ring

Ask authors/readers for more resources

A novel testing device was developed for biomechanical analyses of the pelvis with intact peripelvic soft tissues. The study found that isolated unilateral fractures of the anterior pelvic ring showed no relevant biomechanical variation compared to the intact situation under isolated axial load.
Purpose Biomechanical studies of the pelvis are usually performed using dissected pelvic specimens or synthetic bones. Thereby the stabilising effect of the surrounding soft tissues is analysed insufficiently. Biomechanical data for isolated anterior pelvic ring fractures are currently missing. Therefore, the purpose of this study was to develop a novel testing device for biomechanical analyses of the pelvis and to investigate two different anterior pelvic ring fractures in a cadaveric model with intact peripelvic soft tissues. Methods A new biomechanical table construction which enables the fixation and testing of complete cadaveric specimens was developed. It was used to investigate the relative motion and stiffness changes due to unilateral osteotomy of the superior and inferior pubic ramus. Five cadavers with a mean age of 55.6 years (+/- 15.53 years) were included and loaded with a sinusoidal, cyclic (1 Hz), compressive force of up to 365 N over ten cycles for each condition. Results Biomechanical testing of the pelvis with complete appended soft tissues was feasible. Native stiffness without a pelvic fracture was 64.31 N/mm (+/- 8.33 N/mm). A standardised unilateral osteotomy of the superior pubic ramus reduced the stiffness under isolated axial load by 2% (63.05 N/mm +/- 7.45 N/mm, p = 0.690). Additional osteotomy of the inferior pubic ramus caused a further, statistically not significant, decrease by 5% (59.57 N/mm +/- 6.84 N/mm, p = 0.310). Conclusions The developed test device was successfully used for biomechanical analyses of the pelvis with intact peripelvic soft tissues. In a first study, isolated unilateral fractures of the anterior pelvic ring showed no relevant biomechanical variation compared to the intact situation under isolated axial load. Only 7% of the measured stiffness was created by both unilateral pubic rami. Therefore, the clinical practice to treat unilateral anterior pelvic ring fractures conservatively is supported by the results of this study.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available