4.2 Article

Accuracy of Conductivity Wire-Mesh Sensor in Dependence of Bubble Size

Journal

CHEMIE INGENIEUR TECHNIK
Volume 91, Issue 11, Pages 1696-1701

Publisher

WILEY-V C H VERLAG GMBH
DOI: 10.1002/cite.201900022

Keywords

Bubble sizes; Bubble columns; Multiphase flow instrumentation; Wire-mesh sensors

Ask authors/readers for more resources

An experimental study to assess the accuracy of a wire-mesh sensor with a temporal and spatial resolution of 5 kHz and 4.8 mm in dependence of bubble size has been carried out. As a reference, single air bubbles with a defined bubble size of 2 - 12 mm are injected in a stagnant liquid phase. The results show a higher uncertainty for bubble diameters below the grid resolution of the sensor. In this case, the bubble size depends strongly on the local bubble position within the mesh grid during its passage.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available