4.7 Article

Simultaneous determination of legacy and emerging organophosphorus flame retardants and plasticizers in indoor dust using liquid and gas chromatography-tandem mass spectrometry: method development, validation, and application

Journal

ANALYTICAL AND BIOANALYTICAL CHEMISTRY
Volume 411, Issue 26, Pages 7015-7025

Publisher

SPRINGER HEIDELBERG
DOI: 10.1007/s00216-019-02078-5

Keywords

Simultaneous determination; Organophosphorus flame retardants; Plasticizers; Indoor dust; Liquid chromatography; Tandem mass spectrometry

Ask authors/readers for more resources

In the present study, an analytical method has been developed and validated for the simultaneous detection and quantification of 19 PFRs (14 legacy organophosphorus flame retardants (PFRs) and 5 emerging PFRs (ePFRs)) and 20 plasticizers (7 legacy plasticizers (LPs) and 13 alternative plasticizers (APs)). Sample preparation was based on the combination of previously validated analytical protocols including ultrasonic extraction and Florisil fractionation/cleanup. The analysis was performed by using liquid chromatography-tandem mass spectrometry (LC-MS/MS) for all targeted compounds, except for bis (2-ethylhexyl) phthalate (DEHP) and bis (2-ethylhexyl) terephthalate (DEHT), for which the separation of the isomers resulted in more favorable gas chromatography-electron ionization-mass spectrometry (GC-EI-MS). The new method was in-house validated by applying two levels of fortification in dust. The achieved linearity (R-2) ranged between 0.993 and 0.999. Limits of detection and quantification (LODs and LOQs) ranged between 1 and 265 ng/g and between 1 and 870 ng/g for all analytes, respectively, except for DEHP and DEHT, for which relatively higher LODs (665 and 1100 ng/g, respectively) and LOQs (2100 and 3500 ng/g, respectively) were observed. Accuracy ranged between 75 and 125% for most of the targeted analytes, and repeatability was good with relative standard deviation (RSD) < 15% for most compounds. Finally, the method was applied for the determination and quantification of the targeted chemicals in house dust samples (n = 10) from the megacity of Guangzhou (China). Median values ranged from 3 to 210 ng/g for PFRs, from 4 to 165 ng/g for ePFRs, from 30 to 100,000 ng/g for LPs, and from 6 to 34,000 ng/g for APs. Main contributors to the total contamination were LPs 63% and APs 37% in total plasticizers, whereas PFRs and ePFRs contributed 90% and 10% in total flame retardants. Graphical abstract

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available