4.6 Article

Validation of IMPROD biparametric MRI in men with clinically suspected prostate cancer: A prospective multi-institutional trial

Journal

PLOS MEDICINE
Volume 16, Issue 6, Pages -

Publisher

PUBLIC LIBRARY SCIENCE
DOI: 10.1371/journal.pmed.1002813

Keywords

-

Funding

  1. Instrumentarium Research Foundation
  2. Sigrid Juselius Foundation
  3. Turku University Hospital
  4. TYKS-SAPA research fund
  5. Finnish Cancer Society
  6. Finnish Cultural Foundation
  7. Orion Research Foundation
  8. Academy of Finland
  9. Cancer Foundation Finland sr [180141] Funding Source: researchfish

Ask authors/readers for more resources

Background Magnetic resonance imaging (MRI) combined with targeted biopsy (TB) is increasingly used in men with clinically suspected prostate cancer (PCa), but the long acquisition times, high costs, and inter-center/reader variability of routine multiparametric prostate MRI limit its wider adoption. Methods and findings The aim was to validate a previously developed unique MRI acquisition and reporting protocol, IMPROD biparametric MRI (bpMRI) (NCT01864135), in men with a clinical suspicion of PCa in a multi-institutional trial (NCT02241122). IMPROD bpMRI has average acquisition time of 15 minutes (no endorectal coil, no intravenous contrast use) and consists of T2-weighted imaging and 3 separate diffusion-weighed imaging acquisitions. Between February 1, 2015, and March 31, 2017, 364 men with a clinical suspicion of PCa were enrolled at 4 institutions in Finland. Men with an equivocal to high suspicion (IMPROD bpMRI Likert score 3-5) of PCa had 2 TBs of up to 2 lesions followed by a systematic biopsy (SB). Men with a low to very low suspicion (IMPROD bpMRI Likert score 1-2) had only SB. All data and protocols are freely available. The primary outcome of the trial was diagnostic accuracy-including overall accuracy, sensitivity, specificity, negative predictive value (NPV), and positive predictive value-of IMPROD bpMRI for clinically significant PCa (SPCa), which was defined as a Gleason score >= 3 + 4 (Gleason grade group 2 or higher). In total, 338 (338/364, 93%) prospectively enrolled men completed the trial. The accuracy and NPV of IMPROD bpMRI for SPCa were 70% (113/161) and 95% (71/75) (95% CI 87%-98%), respectively. Restricting the biopsy to men with equivocal to highly suspicious IMPROD bpMRI findings would have resulted in a 22% (75/338) reduction in the number of men undergoing biopsy while missing 4 (3%, 4/146) men with SPCa. The main limitation is uncertainty about the true PCa prevalence in the study cohort, since some of the men may have PCa despite having negative biopsy findings. Conclusions IMPROD bpMRI demonstrated a high NPV for SPCa in men with a clinical suspicion of PCa in this prospective multi-institutional clinical trial.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available