4.7 Article

Occurrence and reduction of antibiotic resistance genes in conventional and advanced drinking water treatment processes

Journal

SCIENCE OF THE TOTAL ENVIRONMENT
Volume 669, Issue -, Pages 777-784

Publisher

ELSEVIER
DOI: 10.1016/j.scitotenv.2019.03.143

Keywords

Antibiotic resistance genes (ARGs); ARG reduction; Ozonation; Chlorination; Drinking water treatment plant (DWTP)

Funding

  1. National Water Pollution Control and Management Technology Major Projects [2017ZX07402003]
  2. Shanghai Municipal Science and Technology Commission [16DZ1204703]
  3. Open Project of State Key Laboratory of Urban Water Resource and Environment [QA201612]
  4. Shanghai Sailing Program [18YF1406000]
  5. China Postdoctoral Science Foundation [2017M621391]
  6. Fundamental Research Funds for the Central Universities [222201814055]

Ask authors/readers for more resources

Antibiotic resistance is extensively detected in drinking water sources, threatening its safety and human health, which deserves further attention to the removal of antibiotic resistance genes (ARGs) in the drinking water system. In this study, the occurrence and reduction of integrase gene intI1 and forty-one ARG subtypes, which confers resistance to six antibiotic classes (beta-lactam, aminoglycoside, macrolide, tetracycline, sulfonamide, and quinolone), were investigated in a drinking water treatment plant (DWTP). Seventeen ARG subtypes with absolute concentrations ranging from 1.4 x 10(0) to 7.3 x 10(5) and 3.9 x 10(4) genes/mL (intI1) were detected in the raw water; and sul1 and sul2 were the two dominant ARG subtypes. Overall, the whole DWTPs achieved 0.03-2.4 log reduction of ARGs compared with those presented in raw water. The reduction efficiencies of sul1, strA, and intI1 were the highest (1.0-2.4 log) in both conventional and advanced processes. However, the levels of sul1, sul2, and ermC still remained high (1.3 x 10(0)-1.9 x 10(4) genes/mL) in finished water. The treatment units, including pre-flocculation/sedimentation/sand filtration, and ozonation units, were beneficial for the reduction of ARGs, which was mostly ascribed to the decline in biomass and the strong oxidizing properties of ozone. However, the reduction effect was subsequently counteracted by the granular activated carbon and chlorination units. This study provides basic data for ARG pollution in the drinking water system, and suggests that ARGs persist in drinking water, even after conventional chlorination or advanced treatment processes, highlighting the need for new and efficient water purification technologies. (C) 2019 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available