4.7 Article

Application of an indoor air pollution metamodel to a spatially-distributed housing stock

Journal

SCIENCE OF THE TOTAL ENVIRONMENT
Volume 667, Issue -, Pages 390-399

Publisher

ELSEVIER
DOI: 10.1016/j.scitotenv.2019.02.341

Keywords

Building physics; I/O ratios; Air pollution; PM2.5; NO2

Funding

  1. National Institute for Health Research Health Protection Research Unit (NIHR HPRU) in Environmental Change and Health at the London School of Hygiene and Tropical Medicine
  2. Public Health England (PHE)
  3. University College London
  4. Wellcome Trust for the 'Complex Urban Systems for Sustainability and Health' (CUSSH) project [205207/Z/16/Z, 209387/Z/17/Z]
  5. University of Exeter
  6. Met Office
  7. Wellcome Trust [205207/Z/16/Z] Funding Source: Wellcome Trust
  8. EPSRC [EP/P022405/1] Funding Source: UKRI

Ask authors/readers for more resources

Estimates of population air pollution exposure typically rely on the outdoor component only, and rarely account for populations spending the majority of their time indoors. Housing is an important modifier of air pollution exposure due to outdoor pollution infiltrating indoors, and the removal of indoor-sourced pollution through active or passive ventilation. Here, we describe the application of an indoor air pollution modelling tool to a spatially distributed housing stock model for England and Wales, developed from Energy Performance Certificate (EPC) data and containing information for approximately 11.5 million dwellings. First, we estimate indoor/outdoor (I/O) ratios and total indoor concentrations of outdoor air pollution for PM2.5 and NO2 for all EPC dwellings in London. The potential to estimate concentration from both indoor and outdoor sources is then demonstrated by modelling indoor background CO levels for England and Wales pre- and post-energy efficient adaptation, including heating, cooking, and smoking as internal sources. In London, we predict a median I/O ratio of 0.60 (99% Cls; 053-0.73) for outdoor PM2.5 and 0.41 (99%Cls; 0.34-0.59) for outdoor NO2; Pearson correlation analysis indicates a greater spatial modification of PM2.5 exposure by housing (rho = 0.81) than NO2 (rho = 0.88). For the demonstrative CO model, concentrations ranged from 0.4-9.9 ppm (99%CIs)(median = 3.0 ppm) in kitchens and 0.3-25.6 ppm (median = 6.4 ppm) in living rooms. Clusters of elevated indoor concentration are found in urban areas due to higher outdoor concentrations and smaller dwellings with reduced ventilation potential, with an estimated 17.6% increase in the number of living rooms and 63% increase in the number of kitchens exceeding recommended exposure levels following retrofit without additional ventilation. The model has the potential to rapidly calculate indoor pollution exposure across large housing stocks and estimate changes to exposure under different pollution or housing policy scenarios. (C) 2019 The Authors. Published by Elsevier B.V.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available