4.6 Article

The mTST - An mHealth approach for training and quality assurance of tuberculin skin test administration and reading

Journal

PLOS ONE
Volume 14, Issue 4, Pages -

Publisher

PUBLIC LIBRARY SCIENCE
DOI: 10.1371/journal.pone.0215240

Keywords

-

Funding

  1. Canadian Institutes for Health Research (CIHR) [FDN-143350]

Ask authors/readers for more resources

Background The Tuberculin Skin Test (TST) is a relatively simple test for detecting latent tuberculosis infection (LTBI) but requires regular quality assurance to ensure proper technique for administration and reading. The objective of this study was to estimate the accuracy and reproducibility of an mhealth approach (the mTST) to measure the size of swelling immediately following TST administration (TST injection bleb) and after 48-72 hours (TST induration). Methods Five non-clinical and one clinical reviewer measured the size of TST injection blebs, and TST indurations using smartphone acquired photos of sites of TST administration and readings in patients, or saline injections in volunteers. The reference standard was the onsite measurement (measured by an experienced TB nurse) of the actual TST injection bleb, or induration. Agreement of reviewers' measurements with the reference standard, as well as agreement within and between reviewers, was estimated using Cohen's kappa coefficient. Results Using the mTST method to assess bleb size in 64 photos of different TST injections, agreement between reviewers, and the reference standard was very good to excellent (kappa ranged from 0.75 to 0.87), and within-reviewer reproducibility of readings was excellent (kappa ranged from 0.86 to 0.96). Using the mTST method to assess TST induration in 72 photos, reviewers were able to detect no induration (< 5mm) and induration of 15mm or greater with accuracy of 95% and 92% respectively, but accuracy was only 20% and 77% for reactions of 5-9mm and 10-14mm respectively. Conclusion The mTST approach appears to be a reliable tool to assess TST administration. The mTST approach was accurate to read indurations of 0-4mm or 15+ mm, but less accurate for reactions of 5-14mm. We believe the mTST approach could be useful for training and quality assurance in locations where on-site supervision is not possible.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available