4.1 Article

Comparison of Three Gaze-position Calibration Techniques in First Purkinje Image-based Eye Trackers

Journal

OPTOMETRY AND VISION SCIENCE
Volume 96, Issue 8, Pages 587-598

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/OPX.0000000000001405

Keywords

-

Categories

Funding

  1. Vice Chancellor's Research Scholarship, Ulster University, Coleraine, United Kingdom
  2. Fast Track for Young Scientist grant

Ask authors/readers for more resources

PURPOSE The purpose of this study was to evaluate the accuracy and repeatability of eccentric-viewing, prism-based, and theoretical techniques that are routinely used to calibrate HR in first Purkinje image-based eye trackers. METHODS Hirschberg ratios of 28 participants (18 to 40 years old) were obtained using the PlusOptix PowerRef 3 photorefractor and eye tracker. In the gold standard eccentric-viewing technique, participants viewed eccentric targets (+/- 12 degrees, 4 degrees steps) at 2 m. In the prism-based technique, 4 to 16 Delta-D base-out and base-in prisms were placed in 4 Delta-D steps before an eye occluded with an infrared filter; the fellow eye fixated a target at 1 m. Each participant's HR was calculated as the slope of the linear regression of the shift in Purkinje image relative to the pupil center for each target eccentricity or induced prism power. Theoretical HR was calculated from the participant's corneal curvature and anterior chamber depth measures. Data collection was repeated on another visit using all three techniques to assess repeatability. Data were also obtained from an Indian cohort (n = 30, 18 to 40 years old) using similar protocols. RESULTS Hirschberg ratio ranged from 10.61 to 14.63 degrees/mm (median, 11.90 degrees/mm) in the eccentric-viewing technique. The prism-based and theoretical techniques demonstrated inaccuracies of 12 and 4% relative to the eccentric-viewing technique. The 95% limits of agreement of intrasubject variability were +/- 2.00, +/- 0.40, and +/- 0.30 degrees/mm for the prism-based, eccentric-viewing, and theoretical techniques, respectively (P > .05). Intraclass correlation coefficients (95% confidence interval) were 0.99 (0.98 to 1.00) for eccentric, 0.99 (0.99 to 1.00) for theoretical, and 0.88 (0.74 to 0.94) for prism-based techniques. Similar results were found for the Indian cohort. CONCLUSIONS The prism-based and theoretical techniques both demonstrated relative inaccuracies in measures of HR compared with the eccentric-viewing technique. The prism-based technique exhibited the poorest repeatability.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.1
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available