4.7 Article

Experimental study on the thermal performance of tunnel lining GHE under groundwater flow

Journal

APPLIED THERMAL ENGINEERING
Volume 106, Issue -, Pages 784-795

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.applthermaleng.2016.06.041

Keywords

Metro tunnel; Tunnel lining GHE; Geothermal energy; Model test; Groundwater flow

Funding

  1. National Natural Science Foundation of China [51308107, 51578146]
  2. Natural Science Foundation of Jiangsu Province [BK20130622]
  3. Specialized Research Fund for the Doctoral Program of Higher Education [20130092120059]
  4. Fundamental Research Funds for Central Universities [2242016K40112]

Ask authors/readers for more resources

The metro tunnel constructed at a depth where the ground temperature is constant meets the basic requirement of a heat source for a ground source heat pump (GSHP) system, and the tunnel lining ground heat exchangers (GHE) transfer the heat through absorber pipes installed in the tunnel lining, which can be used for heating and/or cooling buildings near the tunnel. More and more metro tunnels have been constructed in sandy soil layers with higher permeability in China. In order to evaluate the effect of groundwater on the thermal performance of tunnel lining GHE, a tunnel lining GHE laboratory model test is carried out. The test results show that (i) the groundwater flow velocity that is greater than 1 x 10(-5) m/s is conducive to surrounding rock temperature recovery, the influence regions of the heat exchange on the temperature field of the surrounding rock is about 22.5 cm away from the tunnel lining when the flow rate is less than 1 x 10(-5) m/s; (ii) the groundwater flow can enhance the heat exchange rate of tunnel lining GHE, when the (low velocity changes from I x 10(-4) m/s to 5 x 10(-4) m/s, the heat exchange rate increases by 9.8%, 9.78% and 4.67% after running 8 h when the temperature difference between the inlet temperature of the heat exchange pipes.and the ground temperature are 6.7 degrees C, 11.6 degrees C and 16.7 degrees C, respectively; (iii) the heat exchange rate of the tunnel lining GHE increases linearly with the temperature difference under (he groundwater flow, the growth gradient is 5.10 W/degrees C when the groundwater flow velocity is 5 x 10(-4) m/s; (iv) when the water head and inlet temperature are the same, the cross distribution with a series circuit is good for improving the heat exchange rate. (C) 2016 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available