Stochastic Model Predictive (STOMP) glycaemic control for the intensive care unit: Development and virtual trial validation

Journal

BIOMEDICAL SIGNAL PROCESSING AND CONTROL
Volume 16, Issue -, Pages 61-67

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.bspc.2014.09.011

Keywords

Glycaemic control; Intensive care; Model predictive control; Virtual patients

Funding

  1. UC Summer Scholarship
  2. UC Doctoral Scholarship

Ask authors/readers for more resources

Critically ill patients often experience stress-induced hyperglycaemia, which results in increased morbidity and mortality. Glycaemic control (GC) can be implemented in the intensive care unit (ICU) to safely manage hyperglycaemia. Two protocols SPRINT and STAR, have been implemented in the Christchurch ICU, and have been successful in treating hyperglycaemia while decreasing the risk of hypoglycaemia. This paper presents a new GC protocol that implements the probabilistic, stochastic forecasting methods of STAR, while formalizing the control methodology using model predictive control (MPC) theory to improve the ability to tune the dynamic response of the controller. This Stochastic Model Predictive (STOMP) controller predicts the response to a given insulin/nutrition intervention, and attributes weighted penalty values to several key performance metrics. The controller thus chooses an intervention at each hour that minimizes the sum of these penalties over a prediction window of 6 h, which is twice as long as the 3-h window used in STAR. Clinically validated virtual trials were used to evaluate the relative performance of STOMP. Results showed STOMP was able to obtain results very similar to STAR with both protocols maintaining approximately 85% of time within 4.4-8.0 mmol/L glycaemic band, and only 4-5 patients of the 149 patient STAR cohort having blood glucose (BG) <2.2 mmol/L. STOMP was able to attain similar results to STAR while further increasing ease of controller tuning for different clinical requirements and reducing the number of BG measurements required by 35%. (C) 2014 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available