Tidal volume monitoring by electrical impedance tomography (EIT) using different regions of interest (ROI): Calibration equations

Journal

BIOMEDICAL SIGNAL PROCESSING AND CONTROL
Volume 18, Issue -, Pages 102-109

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.bspc.2014.12.004

Keywords

Electrical impedance tomography (EIT); Respiration; Tidal volume; Regions of interest; COPD

Funding

  1. Direccion de Investigacion y Posgrado (DAIP), Universidad de Guanajuato [FO-DAI-05]
  2. PROMEP-SEP

Ask authors/readers for more resources

A set of calibration equations was previously obtained to transform the lung impedance changes obtained by electrical impedance tomography (EIT), using all frame's elements, into a measurable volume signal. In order to study the goodness of the use of regions of interest (ROI) for lung ventilation monitoring, we considered 6 different ROI to obtain a calibration equation for each area. Our aim was to compare the results, determined by these areas, and those obtained by using all EIT image elements. Two ROI's were defined by those pixels with an impedance change higher than 30% and 70% of the maximum change value. These areas were called P30 and P70, respectively. Two other ROI were defined by bounding two areas by mouse, resembling P30 and P70 regions, which were called M30 and M70, respectively. The remainder was defined by two elliptical areas with an eccentricity of as, and 25 and 32 pixels of mayor axis (E25p and E32p, respectively). Twenty healthy males and 24 chronic obstructive pulmonary disease (COPD) patients were considered. For small region (P30 and M30) we obtained a large dispersion in volume measurement, concluding that small regions are not suitable for monitoring the tidal changes in lung volume even for healthy subjects. The results obtained by the remainder areas, and by using EIT image were similar. Even a slight improvement in data dispersion was obtained by using some ROI. These optimal results, for healthy people, were those corresponding to P70 and M70 (volume dispersion improved from 12% with the whole EIT image to 9% using ROI), and for COPD patients improves volume dispersion from 32% using the whole EIT image to 27% by using E25p. Using not so small ROI, it is possible to estimate the total lung ventilation. (C) 2014 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available