4.5 Article

Fourier-based integration of quasi-periodic gait accelerations for drift-free displacement estimation using inertial sensors

Journal

BIOMEDICAL ENGINEERING ONLINE
Volume 14, Issue -, Pages -

Publisher

BIOMED CENTRAL LTD
DOI: 10.1186/s12938-015-0103-8

Keywords

Gait analysis; Pose estimation; Fourier harmonic analysis; Inertial measurement unit

Funding

  1. Italian Ministry of Education and Research (MIUR) through the research project of national interest (PRIN)
  2. EC [CIP-ICT-PSP-2011-5-297225]
  3. Fondazione Santa Lucia, IRCCS, Ethical Committee [CE/AG4/PROG. 409-29]

Ask authors/readers for more resources

Background: In biomechanical studies Optical Motion Capture Systems (OMCS) are considered the gold standard for determining the orientation and the position (pose) of an object in a global reference frame. However, the use of OMCS can be difficult, which has prompted research on alternative sensing technologies, such as body-worn inertial sensors. Methods: We developed a drift-free method to estimate the three-dimensional (3D) displacement of a body part during cyclical motions using body-worn inertial sensors. We performed the Fourier analysis of the stride-by-stride estimates of the linear acceleration, which were obtained by transposing the specific forces measured by the tri-axial accelerometer into the global frame using a quaternion-based orientation estimation algorithm and detecting when each stride began using a gait-segmentation algorithm. The time integration was performed analytically using the Fourier series coefficients; the inverse Fourier series was then taken for reconstructing the displacement over each single stride. The displacement traces were concatenated and spline-interpolated to obtain the entire trace. Results: The method was applied to estimate the motion of the lower trunk of healthy subjects that walked on a treadmill and it was validated using OMCS reference 3D displacement data; different approaches were tested for transposing the measured specific force into the global frame, segmenting the gait and performing time integration (numerically and analytically). The width of the limits of agreements were computed between each tested method and the OMCS reference method for each anatomical direction: Medio-Lateral (ML), VerTical (VT) and Antero-Posterior (AP); using the proposed method, it was observed that the vertical component of displacement (VT) was within +/- 4 mm (+/- 1.96 standard deviation) of OMCS data and each component of horizontal displacement (ML and AP) was within +/- 9 mm of OMCS data. Conclusions: Fourier harmonic analysis was applied to model stride-by-stride linear accelerations during walking and to perform their analytical integration. Our results showed that analytical integration based on Fourier series coefficients was a useful approach to accurately estimate 3D displacement from noisy acceleration data.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available