Assessment of PMU-based wide-area angle criterion for fault detection in microgrid

Journal

IET GENERATION TRANSMISSION & DISTRIBUTION
Volume 13, Issue 19, Pages 4301-4310

Publisher

INST ENGINEERING TECHNOLOGY-IET
DOI: 10.1049/iet-gtd.2019.0027

Keywords

distributed power generation; fault diagnosis; synchronisation; phasor measurement; power system measurement; power distribution faults; power distribution system; serious protection challenges; effective fault detection scheme; reliable fault detection scheme; present-day microgrid environment; phasor measurement unit-based wide-area phase angle criterion; protection system; voltage phase angle difference; fault point; accurate measurement; faithful measurement; faulted conditions; phasor data concentrator; time synchronised phasor data; protection index; effective fault detection measure; microgrid including large variations; PMU-based wide-area angle criterion; distributed generation

Funding

  1. Central Power Research Institute, Bangalore, Government of India [RSOP/20157/DG/3/15122015]

Ask authors/readers for more resources

The penetration of distributed generation in the power distribution system has increased significantly in recent years, bringing serious protection challenges. Hence, it is mandated to develop effective and reliable fault detection scheme for present-day microgrid environment. This study presents a phasor measurement unit-based (PMU) wide-area phase angle criterion for building a protection system for the microgrid. The absolute value of the rate of change of voltage phase angle difference between the point of common coupling and the bus closest to the fault point is utilised for fault detection in grid connected as well as in the islanded modes of operation. C37.118.1 complied PMUs are employed at the appropriate locations for accurate and faithful measurement of voltage phase angle and the rate of angle difference (RAD) for detecting faulted conditions. PMUs are connected to phasor data concentrator, which receives the time synchronised phasor data and acts as a centralised processing unit. The proposed protection index has been extensively validated on MATLAB/Simulink environment as well as the real-time digital simulator with external PMUs. The test results show that the proposed RAD is a potential candidate for providing effective fault detection measure for microgrid including large variations in operating conditions.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available