4.7 Article

Effect of fire-related temperatures on natural stones

Journal

CONSTRUCTION AND BUILDING MATERIALS
Volume 212, Issue -, Pages 92-101

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.conbuildmat.2019.03.333

Keywords

Natural stone; Fire-related temperatures; Derivatograph; Optical microscope

Funding

  1. Janos Bolyai Research Scholarship of the Hungarian Academy of Sciences
  2. Higher Education Excellence Program of the Ministry of Human Capacities

Ask authors/readers for more resources

In our research, stones were tested after exposing them to temperature load to get information about the changes in their properties and about the limits of applicability. The tested stones are types that are widely used as tiles in Hungary (granite, marble, travertine, labradorite). Beside flexural strength, among our laboratory tests uniaxial compressive strength and tensile strength tests were carried out. The stone material was also examined with optical microscope and derivatograph as well. Based on the experimental results the travertine is recommended for tiles and for load bearing compressed structural elements and the labradorite is recommended for load bearing compressed structural elements. (C) 2019 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available