4.4 Article

Adjuvant radiotherapy-induced cardiac changes among patients with early breast cancer: a three-year follow-up study*

Journal

ACTA ONCOLOGICA
Volume -, Issue -, Pages -

Publisher

TAYLOR & FRANCIS LTD
DOI: 10.1080/0284186X.2019.1630751

Keywords

-

Categories

Funding

  1. Pirkanmaa Hospital District Science Center
  2. Elna Kaarina Savolainen fund
  3. Seppo Nieminen fund
  4. Finnish Cultural Foundation
  5. Pirkanmaa Regional fund
  6. Finnish Foundation of Cardiovascular Research

Ask authors/readers for more resources

Background: In this study, we evaluate the evolution of cardiac changes during a three-year follow-up after adjuvant breast radiotherapy (RT). Methods: Sixty patients with left-sided and 20 patients with right-sided early stage breast cancer without chemotherapy were included in this prospective study. Echocardiography and cardiac biomarkers were evaluated before, immediately after and 3 years after RT. Radiation doses to cardiac structures were calculated. Results: In echocardiography, left ventricle (LV) systolic measurements had impaired at 3 years compared to baseline: the mean global longitudinal strain (GLS) worsened from -18 +/- 3 to -17 +/- 3 (p = .015), LV ejection fraction from 62 +/- 5% to 60 +/- 4% (p = .003) and the stroke volume from 73 +/- 16 mL to 69 +/- 15 mL (p = .015). LV diastolic function was also negatively affected: the isovolumetric relaxation time was prolonged (p = .006) and the first peak of diastole decreased (p = .022). Likewise, left atrial (LA) measurements impaired. These changes in echocardiography were more prominent in left-sided than in right-sided patients. The concurrent aromatase inhibitor (AI) use was associated with GLS impairment. In all patients, the N-terminal pro-brain natriuretic peptide (proBNP) values were median (interquartile range) 74 (41-125) ng/L at baseline, 75 (41-125) ng/L at the end of RT and 96 (56-162) ng/L at 3 years (p < .001 from baseline to 3 years). However, proBNP did not increase in right-sided patients. Conclusion: During the 3-year follow-up after RT, negative subclinical changes in cardiac biomarkers and in LV systolic and diastolic function were observed. The measured changes were more pronounced in left-sided patients. In addition, AI use was associated with impaired cardiac systolic function.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available