4.6 Article

A Comparison of Reflective Photoplethysmography for Detection of Heart Rate, Blood Oxygen Saturation, and Respiration Rate at Various Anatomical Locations

Related references

Note: Only part of the references are listed.
Article Health Care Sciences & Services

Methodological Shortcomings of Wrist-Worn Heart Rate Monitors Validations

Francesco Sartor et al.

JOURNAL OF MEDICAL INTERNET RESEARCH (2018)

Article Anesthesiology

Determination of saturation, heart rate, and respiratory rate at forearm using a Nellcor™ forehead SpO2-saturation sensor

Jarkko Harju et al.

JOURNAL OF CLINICAL MONITORING AND COMPUTING (2017)

Article Medicine, General & Internal

Wearable Pulse Oximetry Measurements on the Torso, Arms, and Legs: A Proof of Concept

Marcus Kramer et al.

MILITARY MEDICINE (2017)

Article Biochemical Research Methods

Robust respiration detection from remote photoplethysmography

Mark van Gastel et al.

BIOMEDICAL OPTICS EXPRESS (2016)

Article Biophysics

Electro-resistive bands for non-invasive cardiac and respiration monitoring, a feasibility study

Gaetano D. Gargiulo et al.

PHYSIOLOGICAL MEASUREMENT (2015)

Article Computer Science, Information Systems

Estimation of Respiratory Rate From Photoplethysmographic Imaging Videos Compared to Pulse Oximetry

Walter Karlen et al.

IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS (2015)

Article Engineering, Electrical & Electronic

A Wearable Contactless Sensor Suitable for Continuous Simultaneous Monitoring of Respiration and Cardiac Activity

Gaetano D. Gargiulo et al.

JOURNAL OF SENSORS (2015)

Article Anesthesiology

Pulse oximetry-derived respiratory rate in general care floor patients

Paul S. Addison et al.

JOURNAL OF CLINICAL MONITORING AND COMPUTING (2015)

Article Biophysics

Investigation of photoplethysmographs from the anterior fontanelle of neonates

J. M. May et al.

PHYSIOLOGICAL MEASUREMENT (2014)

Review Cardiac & Cardiovascular Systems

Pulse oximetry: Understanding its basic principles facilitates appreciation of its limitations

Edward D. Chan et al.

RESPIRATORY MEDICINE (2013)

Article Health Care Sciences & Services

Relationship Between Measurement Site and Motion Artifacts in Wearable Reflected Photoplethysmography

Yuka Maeda et al.

JOURNAL OF MEDICAL SYSTEMS (2011)

Review Surgery

Patterns of unexpected in-'hospital deaths: a root cause analysis

Lawrence A. Lynn et al.

PATIENT SAFETY IN SURGERY (2011)

Article Optics

Estimation of the spectral absorption of light by components of human skin

V. V. Barun et al.

OPTICS AND SPECTROSCOPY (2009)

Article Emergency Medicine

Pulse Oximetry in Emergency Medicine

James M. Callahan

EMERGENCY MEDICINE CLINICS OF NORTH AMERICA (2008)

Review Anesthesiology

The Light-Tissue Interaction of Pulse Oximetry

Paul D. Mannheimer

ANESTHESIA AND ANALGESIA (2007)