4.5 Review

Re-examination of accelerometer data processing and calibration for the assessment of physical activity intensity

Journal

SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS
Volume 29, Issue 10, Pages 1442-1452

Publisher

WILEY
DOI: 10.1111/sms.13470

Keywords

acceleration; counts; energy expenditure; frequency filtering; mechanical work

Categories

Funding

  1. University of Gothenburg and Vastra Gotalandsregionen ALF funding

Ask authors/readers for more resources

This review re-examines the use of accelerometer and oxygen uptake data for the assessment of activity intensity. Accelerometers capture mechanical work, while oxygen uptake captures the energy cost of this work. Frequency filtering needs to be considered when processing acceleration data. A too restrictive filter attenuates the acceleration signal for walking and, to a higher degree, for running. This measurement error affects shorter (children) more than taller (adults) individuals due to their higher movement frequency. Less restrictive filtering includes more movement-related signals and provides measures that better capture mechanical work, but may include more noise. An optimal filter cut-point is determined where most relevant acceleration signals are included. Further, accelerometer placement affects what part of mechanical work being captured. While the waist placement captures total mechanical work and therefore contributes to measures of activity intensity equivalent by age and stature, the thigh and wrist placements capture more internal work and do not provide equivalent measures. Value calibration of accelerometer measures is usually performed using measured oxygen uptake with the metabolic equivalent of task (MET) as reference measure of activity intensity. However, the use of MET is not stringent and is not a measure of activity intensity equivalent by age and stature. A candidate measure is the mass-specific net oxygen uptake, VO(2)net (VO(2)tot - VO(2)stand). To improve measurement of physical activity intensity using accelerometers, research developments are suggested concerning the processing of accelerometer data, use of energy expenditure as reference for activity intensity, and calibration procedure with absolute versus relative intensity.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available