4.3 Article

The utility of the acromion marker cluster (AMC) in a clinical population

Journal

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.jelekin.2019.04.002

Keywords

Scapula; Motion capture; Breast cancer; Data accuracy; Shoulder

Funding

  1. Natural Sciences and Engineering Research Council

Ask authors/readers for more resources

This study investigated the utility of the acromion marker cluster (AMC) method in tracking scapular motion in breast cancer survivors (BCS) and age-matched controls. The results showed that the double calibration (DC) method improved the estimation of scapular orientation compared to the single calibration (SC) method, especially at higher arm elevations. The study suggests that the AMC method with DC is a non-invasive and accurate method for measuring scapular motion in BCS and controls.
Introduction: The acromion marker cluster (AMC) is a non-invasive scapular motion tracking method. However, it lacks testing in clinical populations, where unique challenges may present. This investigation resolved the utility of the AMC approach in a compromised clinical population. Methods: The upper body of breast cancer survivors (BCS) and controls were tracked via motion capture and scapular landmarks palpated and recorded using a digitizer at static neutral to maximum elevation postures. The AMC tracked the scapula during dynamic maximum arm abduction. Both single (SC) and double calibration (DC) methods were applied to calculate scapular angles. The influences of calibration method, elevation, and group on mean and absolute error with two-way fixed ANOVAs with interactions (p < 0.05). Root mean square errors (RMSE) were calculated and compared. Results: DC improved AMC estimation of palpated scapular orientation over SC, especially at higher arm elevations; RMSE averaged 11 degrees higher for SC than DC at maximum elevation, but the methods were only 2.2 degrees different at 90 degrees elevation. DC of the AMC yielded mean error values of similar to 5-10 degrees. These approximate errors reported for AMC with young, lean adults. Conclusions: The AMC with DC is a non-invasive method with acceptable error for measuring scapular motion of BCS and age-matched controls.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available