4.5 Article

Development of Neutron Detector Based on Gd3Ga3Al2O12:Ce Single Crystals

Journal

IEEE TRANSACTIONS ON NUCLEAR SCIENCE
Volume 66, Issue 4, Pages 724-728

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TNS.2019.2900440

Keywords

Detector; scintillator; single crystal; thermal neutron

Ask authors/readers for more resources

Single crystals of Gd3Ga3Al2O12:Ce were grown successfully and a slice having thickness lesser than 1 mm was processed from the grown crystals to setup a portable thermal neutron detector. The presence of Gd isotopes having very high thermal neutron capture cross section ensures almost 100% stopping efficiency in such a low thickness. On the other hand, a lower thickness provided a better discrimination from gamma background. In addition to the continuum gamma, Gd isotopes also produce low-energy conversion electrons and X-rays which could be successfully observed in the form of well discriminated photopeaks at 34 and 74 keV. These photopeaks could also be measured in nuclear reactor beam lines with high gamma background.