4.6 Article

Real-time monitoring and model-based prediction of purity and quantity during a chromatographic capture of fibroblast growth factor 2

Journal

BIOTECHNOLOGY AND BIOENGINEERING
Volume 116, Issue 8, Pages 1999-2009

Publisher

WILEY
DOI: 10.1002/bit.26984

Keywords

ATR-FTIR; dsDNA; fluorescence; HCP; MALS; online sensors

Funding

  1. Osterreichische Forschungsforderungsgesellschaft [824186]
  2. Austrian Federal Ministry for Digital and Economic Affairs (bmwd)
  3. Federal Ministry for Transport, Innovation and Technology (bmvit)
  4. Styrian Business Promotion Agency (SFG)
  5. Standortagentur Tirol
  6. Government of Lower Austria
  7. ZIT - Technology Agency of the City of Vienna through the COMET-Funding Program

Ask authors/readers for more resources

Process analytical technology combines understanding and control of the process with real-time monitoring of critical quality and performance attributes. The goal is to ensure the quality of the final product. Currently, chromatographic processes in biopharmaceutical production are predominantly monitored with UV/Vis absorbance and a direct correlation with purity and quantity is limited. In this study, a chromatographic workstation was equipped with additional online sensors, such as multi-angle light scattering, refractive index, attenuated total reflection Fourier-transform infrared, and fluorescence spectroscopy. Models to predict quantity, host cell proteins (HCP), and double-stranded DNA (dsDNA) content simultaneously were developed and exemplified by a cation exchange capture step for fibroblast growth factor 2 expressed in Escherichia coliOnline data and corresponding offline data for product quantity and co-eluting impurities, such as dsDNA and HCP, were analyzed using boosted structured additive regression. Different sensor combinations were used to achieve the best prediction performance for each quality attribute. Quantity can be adequately predicted by applying a small predictor set of the typical chromatographic workstation sensor signals with a test error of 0.85 mg/ml (range in training data: 0.1-28 mg/ml). For HCP and dsDNA additional fluorescence and/or attenuated total reflection Fourier-transform infrared spectral information was important to achieve prediction errors of 200 (2-6579 ppm) and 340 ppm (8-3773 ppm), respectively.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available