4.8 Article

Backfilling rolling cycle amplification with enzyme-DNA conjugates on antibody for portable electrochemical immunoassay with glucometer readout

Journal

BIOSENSORS & BIOELECTRONICS
Volume 132, Issue -, Pages 210-216

Publisher

ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2019.02.051

Keywords

Electrochemical immunoassay; Rolling cycle amplification; Glucometer readout; Enzyme-DNA conjugates; Disease-related biomarker

Funding

  1. National Natural Science Foundation of China [81703750]
  2. MOST-FDCT joint project between the International S&T Cooperation Program of China [2016YFE0121900]
  3. Science and Technology Development Fund of Macau SAR [FDCT 023/2015/AMJ]

Ask authors/readers for more resources

A simple and feasible electrochemical immunosensing protocol with glucometer readout was designed for the detection of low-abundance disease-related biomarker (alpha-fetoprotein; AFP) on the basis of backfilling rolling cycle amplification (RCA) with invertase-DNA(2) conjugates on the detection antibody. The assay consisted of the immunoreaction, RCA reaction, DNA(2)-invertase hybridization and glucose measurement. Initially, a sandwiched immunoreaction was carried out between anti-AFP capture antibody-coated microplate between nanogold-labeled pAb(2) detection antibody conjugated with DNA). primer (DNA(1)-AuNP-pAb(2)) in the presence of target ATP. Thereafter, the carried primers triggered the RCA reaction in the presence of circular DNA template, polymerase and dNTP, to produce numerous repeated oligonucleotide sequences for hybridization with many invertase-DNA(2) conjugates. The carried invertase molecules accompanying the hybridization reaction hydrolyzed sucrose into glucose, thereby resulting in the amplification of the detectable signal on a handheld personal glucometer (PGM). Under optimum conditions, the developed immunoassay exhibited high sensitivity for the quantitative screening of AFP within a dynamic range of 0.1-100 ng mL(-1) at a low detection limit of 0.087 ng mL(-1) Other biomarkers and proteins did not interfere the signals of this system. In addition, this method was utilized to determine human serum samples containing target AFP, and received well-matched results with the referenced enzyme-linked immunosorbent assay (ELISA) method.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available