4.7 Article

4-phenyl-1,2,3-triazole functionalized mesoporous silica SBA-15 as sorbent in an efficient stir bar-supported micro-solid-phase extraction strategy for highly to moderately polar phenols

Journal

TALANTA
Volume 194, Issue -, Pages 377-384

Publisher

ELSEVIER
DOI: 10.1016/j.talanta.2018.10.012

Keywords

SBA-15; Azides; Click reaction; Stir bar-supported micro-solid-phase-extraction; Phenols

Funding

  1. Chemistry Department, King Fand University of Petroleum and Minerals (KFUPM)

Ask authors/readers for more resources

A simple and effective strategy for the extraction of highly to moderately polar phenols in water samples was developed by synthesizing a series of 4-phenyl-1,2,3-triazole functionalized SBA-15 sorbents (xN(3)-Ph-SBA-15; x = 2-10 wt%) via two steps: azide functionalization of SBA-15 and its click reaction with phenylacetylene. The formed sorbents, which have a blend of both polar (1,2,3-triazole) and non-polar (long chain alkyl groups) sites were characterized using magic angle spinning NMR, surface area, pore size/pore volume N-2 adsorption-desorption isotherms, scanning electron microscopy, and Fourier transform infrared spectroscopy. The surface area and pore size/pore volume were seen to decrease with increasing loading of 4-phenyl-1,2,3-triazole. The sorbents were used in a stir bar-supported micro-solid-phase extraction (SB-mu-SPE) for seven selected phenols in 10 mL water samples, and in combination with gas chromatography - mass spectrometry (GC-MS). A wide number of parameters were studied in the method optimization: 10N(3)-Ph-SBA-15 was the best sorbent which performed better using 20 mg dosage; 15 min extraction time; 300 mu L of ethyl acetate as desorption solvent, 20 min desorption time; and ionic strength set at 0.5 g NaCl. The approach provided the desired linearity range for all tested phenols with R-2 value up to 0.9989 and detection limit (LOD) of 0.23-0.37 ng mL(-1). Relative standard deviation (RSD) and relative recovery experiments were tested using phenols spiked at 1, 100 and 400 ng mL(-1). RSD values were calculated in the range of 2.3-7.5% and the relative recoveries in the wastewater matrix successfully presented a range of 88.5-99.2%.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available