4.7 Article

Development of a third-generation biosensor to determine sterigmatocystin mycotoxin: An early warning system to detect aflatoxin B1

Journal

TALANTA
Volume 194, Issue -, Pages 253-258

Publisher

ELSEVIER
DOI: 10.1016/j.talanta.2018.10.032

Keywords

Biosensor; Soybean peroxidase enzyme; Chemically reduced graphene oxide; Sterigmatocystin; Aflatoxin B-1

Funding

  1. Agenda Nacional de Promocion Cientifica y Tecnologica (FONCYT) [PICT 2266/2014]
  2. Consejo Nacional de Investigaciones Cientificas y Tecnicas (CONICET) [PIP 112-201101-00184]
  3. Ministerio de Ciencia y Tecnologia de la Provincia de Cordoba (MINCyT) [PID 050/2010]
  4. Secretaria de Ciencia y Tecnica (SECyT) from Universidad Nacional de Rio Cuarto [331/16, PPI 2016-2018]
  5. CONICET

Ask authors/readers for more resources

A third-generation enzymatic biosensor was developed to quantify sterigmatocystin (STEH). It was based on a glassy carbon electrode modified with a composite of the soybean peroxidase enzyme (SPE) and chemically reduced graphene oxide. The optimal conditions to construct the biosensor were obtained through an experimental design based on the response surfaces methodology. The experiments were performed in 0.1 mol L-1 phosphate buffer solution, pH 5. Amperometric measurements were carried out at -0.09 V vs Ag/AgCl (3 mol L-1 NaCl). The biosensor showed a lineal response in the concentration range from 6.9 x 10(-9) to 5.0 x 10(-7) mol L-1. The limit of detection was 2.3 x 10(-9) mol L-1 for a signal: noise ratio of 3: 1. Values of the apparent Michaellis-Menten constant, K-M(app), obtained by using both Lineweaver-Burk and Eadi-Hofstee methods were (1.5 +/- 0.2) x 10(-6) and (1.2 +/- 0.2) x 10(-6) mol L-1, respectively. STEH was analyzed in corn samples spiked with STEH, with an average recovery of 96.5%. The biosensor was also used to determine STEH in corn samples inoculated with the Aspergillus flavus fungus, which is an aflatoxins producer. Considering that STEH is a precursor of aflatoxin B-1 (AFB(1)) in its biological transformation, its decrease over time was related to the production of AFB(1). The STEH concentration determined using the biosensor was in very good agreement with that determined by HPLC.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available