4.6 Article

Quasi-static Analysis Based on an Equivalent Circuit Model for a CMOS Terahertz Plasmon Detector in the Subthreshold Region

Journal

SENSORS
Volume 19, Issue 7, Pages -

Publisher

MDPI
DOI: 10.3390/s19071508

Keywords

equivalent circuit model; CMOS plasmon detector; terahertz detector; detector optimization; small-signal analysis; sub-threshold operation; quasi-static

Funding

  1. Basic Science Research Program through the National Research Foundation of Korea (NRF) - Ministry of Science, ICT and Future Planning [2017R1C1B2002285]
  2. IC Design Education Center (IDEC), Korea
  3. National Research Foundation of Korea [2017R1C1B2002285] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

Ask authors/readers for more resources

An analytic method for a complementary metal-oxide-semiconductor (CMOS) terahertz plasmon detector operating in the subthreshold region is presented using the equivalent circuit model. With respect to design optimization of the detector, the signal transmission from the antenna port to the output of the detector is described by using the proposed circuit model, which does not include a complicated physical operating principle and mathematical expressions. Characteristics from the antenna port to the input gate node of the detector are analyzed through the superposition method by using the characteristic impedance of transmission lines. The superposition method shows that the effect of interconnection lines at the input is simplified with the optimum bias point. The characteristics of the plasmon detection are expressed by using small-signal analysis of the single transistor at the sub-threshold operation. The results of the small-signal analysis show that the unity gain preamplifier located between the detector core and the main amplifier can improve the detection performances such as the voltage responsivity and the noise equivalent power. The measurement results using the fabricated CMOS plasmon detector at 200 GHz suggest that the unity gain preamplifier improves the detector performances, which are the same results as we received from the proposed analytic method.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available