4.6 Article

Higher SNR PET image prediction using a deep learning model and MRI image

Journal

PHYSICS IN MEDICINE AND BIOLOGY
Volume 64, Issue 11, Pages -

Publisher

IOP Publishing Ltd
DOI: 10.1088/1361-6560/ab0dc0

Keywords

positron emission tomography; deep learning; neural network

Funding

  1. National Institute of Biomedical Imaging and Bioengineering (NIBIB) [R01EB000194, R21EB026668]

Ask authors/readers for more resources

PET images often suffer poor signal-to-noise ratio (SNR). Our objective is to improve the SNR of PET images using a deep neural network (DNN) model and MRI images without requiring any higher SNR PET images in training. Our proposed DNN model consists of three modified U-Nets (3U-net). The PET training input data and targets were reconstructed using filtered-backprojection (FBP) and maximum likelihood expectation maximization (MLEM), respectively. FBP reconstruction was used because of its computational efficiency so that the trained network not only removes noise, but also accelerates image reconstruction. Digital brain phantoms downloaded from BrainWeb were used to evaluate the proposed method. Poisson noise was added into sinogram data to simulate a 6 min brain PET scan. Attenuation effect was included and corrected before the image reconstruction. Extra Poisson noise was introduced to the training inputs to improve the network denoising capability. Three independent experiments were conducted to examine the reproducibility. A lesion was inserted into testing data to evaluate the impact of mismatched MRI information using the contrast-to-noise ratio (CNR). The negative impact on noise reduction was also studied when miscoregistration between PET and MRI images occurs. Compared with 1U-net trained with only PET images, training with PET/MRI decreased the mean squared error (MSE) by 31.3% and 34.0% for 1U-net and 3U-net, respectively. The MSE reduction is equivalent to an increase in the count level by 2.5 folds and 2.9 folds for 1U-net and 3U-net, respectively. Compared with the MLEM images, the lesion CNR was improved 2.7 folds and 1.4 folds for 1U-net and 3U-net, respectively. The results show that the proposed method could improve the PET SNR without having higher SNR PET images.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available