4.6 Article

Diagnostic value of ultrasound in calcium pyrophosphate deposition disease of the knee joint

Journal

OSTEOARTHRITIS AND CARTILAGE
Volume 27, Issue 5, Pages 781-787

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.joca.2018.11.013

Keywords

Calcium pyrophosphate deposition disease; Ultrasound; Diagnosis; Accuracy; Reliability

Funding

  1. Basic Science Research Program through the National Research Foundation of Korea (NRF) - Ministry of Education, Science and Technology, Republic of Korea [NRF-2018R1D1A1A02050982]

Ask authors/readers for more resources

Objective: To assess the diagnostic performance of ultrasound (US) for calcium pyrophosphate deposition (CPPD) at the level of menisci, hyaline cartilage (HC), tendons, and synovial fluid (SF) of the knee, and to examine inter-and intra-observer reliability. Design: We consecutively included patients with knee effusion over a 2-year period (43 patients with CPPD and 131 controls). All patients underwent SF analysis, conventional radiography (CR), and US examination using the Outcome Measures in Rheumatology (OMERACT) definition of the US characteristics of CPPD. Two independent operators performed the US, and inter-observer agreement was calculated. Intra-observer agreement was examined with static images obtained for all enrolled patients. Results: US revealed calcium pyrophosphate (CPP) deposits in menisci, HC, and tendon more frequently in patients with CPPD than in control patients. The presence of US CPP deposits in SF was not significantly different between the two groups. Combined US evaluation of the three components (menisci, HC, and tendon) showed the best diagnostic performance. The sensitivity and specificity for US evaluation of the three components were 74.4% and 77.1%, respectively, while for CR evaluation, the sensitivity and specificity were 44.2% and 96.9%, respectively. Inter-and intra-observer agreement were excellent for medial (kappa = 0.930, 0.972) and lateral menisci (kappa = 0.905, 0.942), HC (kappa = 0.844, 0.957), and SF (kappa = 0.817, 0.925). Tendon showed fair inter-observer (kappa = 0.532) and good intra-observer reliability (kappa = 0.788). Conclusions: Based on the OMERACT definition, US demonstrated better diagnostic capacity than CR to diagnose CPPD, with excellent reliability. Combined evaluation of menisci, HC, and tendon showed the best diagnostic accuracy. (C) 2019 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available