4.6 Article

Compact and sensitive mid-infrared all-fiber quartz-enhanced photoacoustic spectroscopy sensor for carbon monoxide detection

Journal

OPTICS EXPRESS
Volume 27, Issue 6, Pages 9302-9312

Publisher

OPTICAL SOC AMER
DOI: 10.1364/OE.27.009302

Keywords

-

Categories

Funding

  1. National Natural Science Foundation of China [61875047]
  2. Natural Science Foundation of Heilongjiang Province of China [JJ2019YX0173]
  3. Fundamental Research Funds for the Central Universities
  4. Heilongjiang Provincial Postdoctoral Science Foundation [LBHQ18052]
  5. Application Technology Research and Development Projects of Harbin [2016RAQXJ140]
  6. National Science Foundation (NSF) (ERC MIRTHE award)
  7. Welch Foundation [C-0586]

Ask authors/readers for more resources

A compact and sensitive quartz-enhanced photoacoustic spectroscopy (QEPAS) based sensor for carbon monoxide (CO) detection was demonstrated by using a mid-infrared all-fiber structure as well as a 3D-printed acoustic detection module. An all-fiber configuration has advantages of easier optical alignment, lower insertion loss improvement in system stability, reduction in sensor size and lower cost. The 3D-printed acoustic detection module was introduced to match the mid-infrared all-fiber structure and further decrease the sensor volume, which resulted in a small size of 3.5 cm(3) and a weight of 5 grams. A 2.33 mu m distributed feedback fiber-coupled diode laser was used as the laser excitation source. A custom quartz tuning fork (QTF) with a small-gap of 200 mu m was used as the acoustic wave transducer in order to improve the signal level of the QEPAS sensor. An acoustic micro resonator was utilized as the acoustic wave enhancer. The gas pressure and laser wavelength modulation depth were optimized, respectively. Water vapor was used to accelerate the vibrational-translational relaxation rate of the targeted CO molecule. Finally, a minimum detection limit (MDL) of 4.2 part per million (ppm) was achieved, corresponding to a normalized noise equivalent absorption (NNEA) coefficient of 7.4 x 10(-9) cm(-1) W/root Hz. An Allan deviation analysis was used to evaluate the long-term stability of the reported CO-QEPAS sensor system. With an integration time of 150 s, the MDL was improved to be 1.3 ppm. (C) 2019 Optical Society of America under the terms of the OSA Open Access Publishing Agreement

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available