4.7 Article

First metabolic profile of PV8, a novel synthetic cathinone, in human hepatocytes and urine by high-resolution mass spectrometry

Journal

ANALYTICAL AND BIOANALYTICAL CHEMISTRY
Volume 408, Issue 18, Pages 4845-4856

Publisher

SPRINGER HEIDELBERG
DOI: 10.1007/s00216-016-9599-4

Keywords

PV8; Novel psychoactive substances; Metabolic profiling; HRMS; Hepatocytes; Synthetic cathinones

Funding

  1. National Institute on Drug Abuse, National Institutes of Health

Ask authors/readers for more resources

Novel psychoactive substances (NPS) are ever changing on the drug market, making it difficult for toxicology laboratory methods to stay current with so many new drugs. Recently, PV8, a synthetic pyrrolidinophenone, was detected in seized products in Japan (2013), The Netherlands (2014), and Germany (2014). There are no controlled PV8 administration studies, and no pharmacodynamic and pharmacokinetic data. The objective was to determine PV8's metabolic stability in human liver microsome (HLM) incubation and its metabolism following human hepatocyte incubation and high-resolution mass spectrometry (HRMS) with a Thermo Scientific Q-Exactive. Data were acquired with a full-scan data-dependent mass spectrometry method. Scans were thoroughly data mined with different data processing algorithms and analyzed in WebMetaBase. PV8 exhibited a relatively short 28.8 min half-life, with an intrinsic 24.2 mu L/min/mg microsomal clearance. This compound is predicted to be an intermediate clearance drug with an estimated human 22.7 mL/min/kg hepatic clearance. Metabolic pathways identified in vitro included: hydroxylation, ketone reduction, carboxylation, N-dealkylation, iminium formation, dehydrogenation, N-oxidation, and carbonylation. The top three in vitro metabolic pathways were di-hydroxylation > ketone reduction > gamma-lactam formation. Authentic urine specimen analyses revealed the top three metabolic pathways were aliphatic hydroxylation > ketone reduction + aliphatic hydroxylation > aliphatic carboxylation, although the most prominent peak was parent PV8. These data provide useful urinary metabolite targets (aliphatic hydroxylation, aliphatic hydroxylation + ketone reduction, aliphatic carboxylation, and di-hydroxylation) for forensic and clinical testing, and focus reference standard companies' synthetic efforts to provide commercially available standards needed for PV8 biological specimen testing.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available