4.5 Article

High-dimensionality undersampled patch-based reconstruction (HD-PROST) for accelerated multi-contrast MRI

Journal

MAGNETIC RESONANCE IN MEDICINE
Volume 81, Issue 6, Pages 3705-3719

Publisher

WILEY
DOI: 10.1002/mrm.27694

Keywords

compressed-sensing; low-rank tensor decomposition; magnetization transfer contrast; MR fingerprinting; multi-contrast MRI; patch-based reconstruction

Funding

  1. EPSRC [EP/P001009/, EP/P032311/1, EP/P007619]
  2. Wellcome EPSRC Centre for Medical Engineering [NS/A000049/1]
  3. National Institute for Health Research (NIHR) comprehensive Biomedical Research Centre
  4. EPSRC [EP/N009258/1, EP/P032311/1, EP/P007619/1] Funding Source: UKRI

Ask authors/readers for more resources

Purpose: To develop a new high-dimensionality undersampled patch-based reconstruction (HD-PROST) for highly accelerated 2D and 3D multi-contrast MRI. Methods: HD-PROST jointly reconstructs multi-contrast MR images by exploiting the highly redundant information, on a local and non-local scale, and the strong correlation shared between the multiple contrast images. This is achieved by enforcing multi-dimensional low-rank in the undersampled images. 2D magnetic resonance fingerprinting (MRF) phantom and in vivo brain acquisitions were performed to evaluate the performance of HD-PROST for highly accelerated simultaneous T-1 and T-2 mapping. Additional in vivo experiments for reconstructing multiple undersampled 3D magnetization transfer (MT)-weighted images were conducted to illustrate the impact of HD-PROST for high-resolution multi-contrast 3D imaging. Results: In the 2D MRF phantom study, HD-PROST provided accurate and precise estimation of the T-1 and T-2 values in comparison to gold standard spin echo acquisitions. HD-PROST achieved good quality maps for the in vivo 2D MRF experiments in comparison to conventional low-rank inversion reconstruction. T-1 and T-2 values of white matter and gray matter were in good agreement with those reported in the literature for MRF acquisitions with reduced number of time point images (500 time point images, similar to 2.5 s scan time). For in vivo MT-weighted 3D acquisitions (6 different contrasts), HD-PROST achieved similar image quality than the fully sampled reference image for an undersampling factor of 6.5-fold. Conclusion: HD-PROST enables multi-contrast 2D and 3D MR images in a short acquisition time without compromising image quality. Ultimately, this technique may increase the potential of conventional parameter mapping.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available