4.7 Article

Durability of Transcatheter and Surgical Bioprosthetic Aortic Valves in Patients at Lower Surgical Risk

Journal

JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY
Volume 73, Issue 5, Pages 546-553

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jacc.2018.10.083

Keywords

aortic bioprosthesis; aortic stenosis; aortic valve durability; transcatheter aortic valve replacement

Funding

  1. Danish Heart Foundation [09-10-AR76-A2733-25400, 12-04R90-A3879-22733, 13-04-R94-A4473-22762]
  2. Medtronic
  3. Abbott
  4. Boston Scientific
  5. Symetis
  6. Edwards Lifesciences
  7. St. Jude Medical

Ask authors/readers for more resources

BACKGROUND Transcatheter aortic valve replacement (TAVR) is an alternative to surgical aortic valve replacement (SAVR) in patients with severe aortic stenosis and intermediate or high surgical risk. OBJECTIVES The aim of this study was to compare the durability of transcatheter and surgical bioprosthetic aortic valves using standardized criteria. METHODS In the NOTION (Nordic Aortic Valve Intervention) trial, all-comer patients with severe aortic stenosis and lower surgical risk for mortality were randomized 1: 1 to TAVR (n = 139) or SAVR (n = 135). Moderate/severe structural valve deterioration (SVD) was defined as a mean gradient >= 20 mm Hg, an increase in mean gradient >= 10 mm Hg from 3 months post-procedure, or more than mild intraprosthetic aortic regurgitation (AR) either new or worsening from 3 months post-procedure. Nonstructural valve deterioration (NSVD) was defined as moderate/severe patient-prosthesis mismatch at 3 months or moderate/severe paravalvular leakage. Bioprosthetic valve failure (BVF) was defined as: valve-related death, aortic valve reintervention, or severe hemodynamic SVD. RESULTS At 6 years, the rates of all-cause mortality were similar for TAVR (42.5%) and SAVR (37.7%) patients (p = 0.58). The rate of SVD was higher for SAVR than TAVR (24.0% vs. 4.8%; p < 0.001), whereas there were no differences in NSVD (57.8% vs. 54.0%; p = 0.52) or endocarditis (5.9% vs. 5.8%; p = 0.95). BVF rates were similar after SAVR and TAVR through 6 years (6.7% vs. 7.5%; p = 0.89). CONCLUSIONS In the NOTION trial through 6 years, SVD was significantly greater for SAVR than TAVR, whereas BVF was low and similar for both groups. Longer-term follow-up of randomized clinical trials will be necessary to confirm these findings. (Nordic Aortic Valve Intervention Trial; NCT01057173) (c) 2019 by the American College of Cardiology Foundation.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available