4.7 Article Proceedings Paper

Enabling industrial production of electrodes by use of slot-die coating for HT-PEM fuel cells

Journal

INTERNATIONAL JOURNAL OF HYDROGEN ENERGY
Volume 44, Issue 25, Pages 12793-12801

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.ijhydene.2018.11.091

Keywords

HT-PEM fuel cell; Single cell testing; Wet reformate; Production upscaling; GDE coating; Benchmarking

Funding

  1. Innovation Fund Denmark
  2. European Commission [325262]

Ask authors/readers for more resources

With high temperature polymer electrolyte membrane fuel cell systems gradually penetrating the commercial market, material manufacturing processes demand re-evaluation for big scale production. Three different methods for electrode production are compared in terms of their suitability and performance. Homogeneity, reproducibility and durability of coated electrodes using hydrogen as well as wet reformate fuel in selected cases are investigated. This shows that the slot-die process has clear advantages in comparison to spraying and tape casting with regard to upscaling potential and film homogeneity. These electrodes have proven to be durable over more than 6000 h, with degradation rates as low as 1 mu V h(-1) over 3000 h of testing. (C) 2019 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved.