4.4 Article

Sensitivity and reliability of cerebral oxygenation responses to postural changes measured with near-infrared spectroscopy

Journal

EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY
Volume 119, Issue 5, Pages 1117-1125

Publisher

SPRINGER
DOI: 10.1007/s00421-019-04101-0

Keywords

Cerebrovascular circulation; Sensitivity; Reliability; Physiology; Orthostatic hypotension; Cerebral autoregulation

Funding

  1. Applied and Engineering Science domain (TTW) of the Netherlands Organization of Scientific Research (NWO): NeuroCIMT-Barocontrol [14901]

Ask authors/readers for more resources

Purpose Cerebral oxygenation as measured by near-infrared spectroscopy (NIRS) might be useful to discriminate between physiological and pathological responses after standing up in individuals with orthostatic hypotension. This study addressed the physiological sensitivity of the cerebral oxygenation responses as measured by NIRS to different types and speeds of postural changes in healthy adults and assessed the reliability of these responses. Methods Cerebral oxygenated hemoglobin (O(2)Hb), deoxygenated hemoglobin (HHb) and tissue saturation index (TSI) were measured bilaterally on the forehead of 15 healthy individuals (12 male, age range 18-27) using NIRS. Participants performed three repeats of sit to stand, and slow and rapid supine to stand movements. Responses were defined as the difference between mean, minimum and maximum O(2)Hb, HHb and TSI values after standing up and baseline. Test-retest, interobserver and intersensor reliabilities were addressed using intraclass correlation coefficients (ICCs). Results The minimum O(2)Hb response was most sensitive to postural changes and showed significant differences (- 4.09 mu mol/L, p < 0.001) between standing up from sitting and supine position, but not between standing up at different speeds (- 0.31 mu mol/L, p = 0.70). The minimum O(2)Hb response was the most reliable parameter (ICC > 0.6). Conclusions In healthy individuals, NIRS-based cerebral oxygenation parameters are sensitive to postural change and discriminate between standing up from supine and sitting position with minimum O(2)Hb response as the most sensitive and reliable parameter. The results underpin the potential value for future clinical use of NIRS in individuals with orthostatic hypotension.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available