Silica bead-based microfluidic device with integrated photodiodes for the rapid capture and detection of rolling circle amplification products in the femtomolar range

Journal

BIOSENSORS & BIOELECTRONICS
Volume 128, Issue -, Pages 68-75

Publisher

ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2018.12.004

Keywords

Photodiodes; Rolling circle amplification; Infectious disease diagnostics; Microfluidics; Silica microbeads

Funding

  1. European Union's Horizon 2020 research and innovation program New Diagnostics for Infectious Diseases (ND4ID) [675412]
  2. Innovative Medicines Initiative 2 Joint Undertaking [722208]
  3. European Union's Horizon 2020 research and innovation programme
  4. EFPIA Partner Sanofi
  5. EFPIA Partner GSK
  6. EFPIA Partner Bayer
  7. EFPIA Partner Rentschler
  8. EFPIA Partner UCB
  9. EFPIA Partner Synthon
  10. EFPIA Partner Pfizer
  11. Fundacao para a Ciencia e a Tecnologia (FCT) [SFRH/BD/97354/2013, PD/BD/135274/2017, SFRH/BD/95079/2013, SFRH/BD/96442/2013]
  12. Fundacao para a Ciencia e a Tecnologia (PCT) through the research project OptLoc [PTDC/BBB-NAN/5927/2014]
  13. Fundacao para a Ciencia e a Tecnologia (FCT) through the Institute of Nanoscience and Nanotechnology [UID/NAN/50024/2013]
  14. Fundação para a Ciência e a Tecnologia [SFRH/BD/96442/2013, SFRH/BD/95079/2013, PD/BD/135274/2017, PTDC/BBB-NAN/5927/2014] Funding Source: FCT

Ask authors/readers for more resources

The rapid and sensitive detection of specific nucleic acid sequences at the point-of-care (PoC) is becoming increasingly in demand for a variety of emergent biomedical applications ranging from infectious disease diagnostics to the screening of antimicrobial resistance. To meet such demand, considerable efforts have been invested towards the development of portable and integrated analytical devices combining microfluidics with miniaturized signal transducers. Here, we demonstrate the combination of rolling circle amplification (RCA)-based nucleic acid amplification with an on-chip size-selective trapping of amplicons on silica beads (similar to 8 nL capture chamber) coupled with a thin-film photodiode (200 x 200 mu m area) fluorescence readout. Parameters such as the flow rate of the amplicon solution and trapping time were optimized as well as the photodiode measurement settings, providing minimum detection limits below 0.5 fM of targeted nucleic acids and requiring only 5 mu L of pre-amplified sample. Finally, we evaluated the analytical performance of our approach by benchmarking it against a commercial instrument for RCA product (RCP) quantification and further investigated the effect of the number of RCA cycles and elongation times (ranging from 10 to 120 min). Moreover, we provide a demonstration of the application for diagnostic purposes by detecting RNA from influenza and Ebola viruses, thus highlighting its suitability for integrated PoC systems.