4.7 Article

Characterizing transport and deposition of particulate pollutants in a two-zone chamber using a Markov chain model combined with computational fluid dynamics

Journal

APPLIED MATHEMATICAL MODELLING
Volume 72, Issue -, Pages 650-662

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.apm.2019.02.035

Keywords

Computational fluid dynamics; Fast prediction; Markov chain model; Multi-zone space; Particle deposition

Funding

  1. National Science & Technology Supporting Program [2015BAJ03B00]
  2. National Natural Science Foundation [51378186]

Ask authors/readers for more resources

Understanding the distribution and spread of indoor airborne contaminants between rooms in a multi-zone space is crucial for protecting human health and indoor environmental control. Predicting the transmission of suddenly released particulate pollutants from one room to another in a rapid and precise manner is important for reducing or even eliminating the risk of cross contamination between occupants. In this study, we developed a modified Markov chain model that considers the effect of gravity to predict the dispersion and deposition of aerosol particles in a two-zone chamber. To perform particle phase simulations, the proposed model couples the data obtained from a steady-state flow field using the computational fluid dynamics (CFD) software Fluent with some codes that we developed in the MATLAB environment. Two examples based on previously reported experimental data were used to validate the proposed model. The results indicate that the proposed model is suitable for modeling the dynamic processes where airborne particles are released from constant and pulsed contaminant sources in multi-zone spaces with reasonable accuracy and computational efficiency. After analyzing particle exposure in the two-zone chamber, we found that the accumulated exposure level in the zone with the constant contaminant source always had a higher rate of increase than the other zones. However, the accumulated exposure level for the pulsed (instantaneous) source was inversely proportional to the air exchange rate for all zones. Compared with traditional CFD models and multi-zone models, our proposed model can balance the accuracy and efficiency when predicting the spread of particulate contaminants in multi-zone spaces by choosing appropriate grid resolution (s) (C) 2019 Elsevier Inc. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available