Energy saving performance assessment and lessons learned from the operation of an active phase change materials system in a multi-storey building in Melbourne

Journal

APPLIED ENERGY
Volume 238, Issue -, Pages 1582-1595

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.apenergy.2019.01.116

Keywords

Phase change materials; Building energy efficiency; Thermal energy storage; Active PCM; PCM heat exchanger; Microencapsulated phase change material

Funding

  1. Australian Research Council Industrial Transformation Research Hub for nanoscience-based construction material manufacturing [IH150100006]
  2. Sustainable Built Environment Naiotnal Research Center
  3. Aurecon
  4. Queensland Government Department of Housing and Public Works
  5. Western Australia Government Department of Finance

Ask authors/readers for more resources

While the energy saving performance of an active phase change materials (PCMs) system in buildings has been widely investigated using prototype-scale experiments and numerical assessments, their performance during the operational phase of a real building has been less understood. This study assessed the energy-saving performance of an active PCM system installed in an eleven storey building in Melbourne. Macro-encapsulated PCM with the phase transition temperature of 15 degrees C was installed in a large PCM tank. Water was used as the heat transfer fluid (HTF) to extract and store cooling energy from the PCM tank. The performance of the active PCM system was monitored for 25 consecutive months, and the results were analyzed on a seasonal basis. Building design documents and the maintenance manuals were studied to understand the difference between design intent and actual operation. The analyzed results revealed that the active PCM system reduced cooling load on the chiller by 12-37% only during colder months, but, remained dormant during the summer. Even in the case of maximum effectiveness, the PCM tank only utilized 15% of its available heat storage capacity to reduce the cooling load. The factors that contributed to the underperformance of active PCM system include mismatch between designed and actual operation of the PCM system, inefficient operation logic of the system, poor material quality, and limited knowledge of maintenance staffs during the operation stage. The lessons learned from the operation of this active PCM system in this multi-storey building were reported and discussed.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available