4.7 Article

Mapping soil moisture across an irrigated field using electromagnetic conductivity imaging

Journal

AGRICULTURAL WATER MANAGEMENT
Volume 163, Issue -, Pages 285-294

Publisher

ELSEVIER
DOI: 10.1016/j.agwat.2015.09.003

Keywords

DUALEM-421; Soil volumetric water content; EM inversion; Water use efficiency

Ask authors/readers for more resources

The ability to measure and map volumetric soil water (theta) quickly and accurately is important in irrigated agriculture. However, the traditional approach of using thermogravimetric moisture (w) and converting this to theta using measurements of bulk density (rho-cm(3)/cm(3)) is laborious and time consuming. To speed up the process electromagnetic (EM) instruments have been used to assist in mapping average theta along a transect or across a field. This is because the apparent soil electrical conductivity (ECa) measured by EM instruments has been shown to be a function of 0, when other soil properties are uniform. However, mapping depth-specific soil theta has been little explored. One possible approach is to invert the ECa data to calculate estimates of true electrical conductivity (sigma) at specific depths (i.e., 0.15, 0.45, 0.75, 1.05 and 1.35 m) and couple this to measured theta. This research explores this possibility by using a single frequency multi-coil DUALEM-421 across a centre-pivot irrigated Lucerne field (Medicago sativa L.) in San Jacinto, CA, USA. The first aim is to determine an optimal set of inversion parameters (i.e., forward modelling, inversion algorithm and damping factor-lambda) which are appropriate to establish a calibration between sigma and theta. In this regard the largest coefficient of determination (R-2 = 0.56) is achieved when we used the FS model, S2 algorithm and a lambda = 0.3. The second aim is to see if all the coil arrays of the DUALEM-421 are necessary. We conclude that while the DUALEM-1 produces a larger R-2 (0.59), the use of the DUALEM-421 data is better (R-2 = 0.56), because the total model misfit (4.70 mSm(-1)) is smaller and because it better accounts for the spatial variation of theta in the subsoil. In terms of predicting theta, the calibration equation (theta = 2.751 + 0.190 x sigma) was examined using a leave-one-out cross validation. The Lin's concordance (0.73) between measured and predicted theta was good. The resulting 2-d depth slices and cross-sections gave insights into the spatial distribution of theta which allowed the inference of depth of saturated soil and location of the wetting front and identified areas where deep drainage may be problematic. The approach has applications for water use and management given it can identify inefficiencies in water application rates and use. (C) 2015 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available