4.6 Article

A Critical Evaluation on the Role of Aerodynamic and Canopy-Surface Conductance Parameterization in SEB and SVAT Models for Simulating Evapotranspiration: A Case Study in the Upper Biebrza National Park Wetland in Poland

Journal

WATER
Volume 10, Issue 12, Pages -

Publisher

MDPI
DOI: 10.3390/w10121753

Keywords

surface energy balance; SVAT; aerodynamic conductance; canopy-surface conductance; evapotranspiration; wetland; Biebrza National Park

Funding

  1. HiWET consortium - Belgian Science Policy (BELSPO)-Fonds National de la Recherche (FNR)-Luxembourg under the program STEREOIII [INTER/STEREOIII/13/03/HiWET, CONTRACT NR SR/00/301]
  2. Luxembourg Institute of Science and Technology (LIST) through the project BIOTRANS [00001145]
  3. CAOS-2 project grant - FNR-DFG [INTER/DFG/14/02]

Ask authors/readers for more resources

Evapotranspiration (ET) estimation through the surface energy balance (SEB) and soil-vegetation-atmosphere-transfer (SVAT) models are uncertain due to the empirical parameterizations of the aerodynamic and canopy-substrate conductances (g(A) and g(S)) for heat and water vapor transfers. This study critically assessed the impact of conductance parameterizations on ET simulation using three structurally different SEB and SVAT models for an ecologically important North-Eastern European wetland, Upper Biebrza National Park (UBNP) in two consecutive years 2015 and 2016. A pronounced ET underestimation (mean bias -0.48 to -0.68 mm day(-1)) in SEBS (Surface Energy Balance System) was associated with an overestimation of g(A) due to uncertain parameterization of momentum roughness length and bare soil's excess resistance to heat transfer (kB(-1)) under low vegetation cover. The systematic ET overestimation (0.65-0.80 mm day(-1)) in SCOPE (Soil Canopy Observation, Photochemistry and Energy fluxes) was attributed to the overestimation of both the conductances. Conductance parameterizations in SEBS and SCOPE appeared to be very sensitive to the general ecohydrological conditions, with a tendency of overestimating g(A) (g(S)) under humid (arid) conditions. Low ET bias in the analytical STIC (Surface Temperature Initiated Closure) model as compared to SEBS/SCOPE indicated the critical need for calibration-free conductance parameterizations for improved ET estimation.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available