4.5 Article

Viridot: An automated virus plaque (immunofocus) counter for the measurement of serological neutralizing responses with application to dengue virus

Journal

PLOS NEGLECTED TROPICAL DISEASES
Volume 12, Issue 10, Pages -

Publisher

PUBLIC LIBRARY SCIENCE
DOI: 10.1371/journal.pntd.0006862

Keywords

-

Funding

  1. Intramural Research Program of the NIH, National Institute of Allergy and Infectious Diseases, National Institutes of Health [R01AI114703-01]
  2. Bill and Melinda Gates Foundation [OPP1104710]

Ask authors/readers for more resources

The gold-standard method for quantifying neutralizing antibody responses to many viruses, including dengue virus (DENV), is the plaque reduction neutralization test (PRNT, also called the immunofocus reduction neutralization test). The PRNT conducted on 96-well plates is high-throughput and requires a smaller volume of antiserum than on 6- or 24-well plates, but manual plaque counting is challenging and existing automated plaque counters are expensive or difficult to optimize. We have developed Viridot (Viridot package), a program for R with a user interface in shiny, that counts viral plaques of a variety of phenotypes, estimates neutralizing antibody titers, and performs other calculations of use to virologists. The Viridot plaque counter includes an automatic parameter identification mode (misses <10 plaques/well for 87% of diverse DENV strains [n = 1521]) and a mode that allows the user to fine-tune the parameters used for counting plaques. We compared standardized manual and Viridot plaque counting methods applied to the same wells by two analyses and found that Viridot plaque counts were as similar to the same analyst's manual count (Lin's concordance correlation coefficient, rho(c) = 0.99 [95% confidence interval: 0.99-1.00]) as manual counts between analysts (rho(c) = 0.99 [95% CI: 0.98-0.99]). The average ratio of neutralizing antibody titers based on manual counted plaques to Viridot counted plaques was 1.05 (95% CI: 0.98-1.14), similar to the average ratio of antibody titers based on manual plaque counts by the two analysts (1.06 [95% CI: 0.84-1.34]). Across diverse DENV and ZIKV strains (n = 14), manual and Viridot plaque counts were mostly consistent (range of rho(c) = 0.74 to 1.00) and the average ratio of antibody titers based on manual and Viridot counted plaques was close to 1 (0.94 [0.86-1.02]). Thus, Viridot can be used for plaque counting and neutralizing antibody titer estimation of diverse DENV strains and potentially other viruses on 96-well plates as well as for formalization of plaque-counting rules for standardization across experiments and analysts.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available