4.4 Review

Effect of calculation method on kidney dosimetry in 177Lu-octreotate treatment

Journal

ACTA ONCOLOGICA
Volume 55, Issue 9-10, Pages 1069-1076

Publisher

TAYLOR & FRANCIS LTD
DOI: 10.1080/0284186X.2016.1182642

Keywords

-

Categories

Ask authors/readers for more resources

Background: Lu-177-octreotate is an effective treatment modality for patients with metastatic neuroendocrine tumors. The kidney is a critical dose-limiting organ in that modality. We investigated the absorbed doses in the kidney and compared whole kidney volume (WKV) and small (4cm(3)) volume of the kidney (SV) methods. We also evaluated a new calculation method that was based on two single photon emission computed tomography/computed tomography (SPECT/CT) scans.Methods: Absorbed radiation doses in the kidneys were calculated for 24 patients with neuroendocrine tumors. All patients received four cycles of Lu-177-octreotate given at eight-week intervals with a mean activity of 7.1 GBq (range 3.28-8.79 GBq). Absorbed doses and half-lives were calculated by the WKV and SV methods. Dosimetry was determined for the cortex and medulla in the first treatment cycle.Results: The mean absorbed radiation dose was 0.440.15Gy/GBq for the WKV method and, 0.74 +/- 0.28Gy/GBq for the SV method. Three patients had a 20% increase of the absorbed dose over the four treatment cycles for the WKV method compared to eight patients for the SV method. The mean absorbed dose in the medulla was 0.62 +/- 0.27Gy/GBq, whereas the mean absorbed dose in the cortex was 0.41 +/- 0.22Gy/GBq. Both regions had similar half-lives. Patients who received lower activities for medical reasons still had similar absorbed doses to kidneys compared to those who received the full activities. Our study indicates that absorbed doses can be calculated reliably using two SPECT/CT scans, at 24 and 168hours after each treatment.Conclusions: Absorbed doses in the kidneys from systemic radionuclide therapy that are measured by the WKV method and SV method cannot be directly compared. There were regional differences within kidneys for the uptake of Lu-177-octreotate. Two SPECT/CTs are sufficient for kidney dosimetry based on our new calculation method.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available